Follow
Edward Castillo
Edward Castillo
Associate Professor, Biomedical Engineering, University of Texas at Austin
Verified email at rice.edu - Homepage
Title
Cited by
Cited by
Year
A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
R Castillo, E Castillo, R Guerra, VE Johnson, T McPhail, AK Garg, ...
Physics in Medicine & Biology 54 (7), 1849, 2009
6362009
Dynamic ventilation imaging from four-dimensional computed tomography
T Guerrero, K Sanders, E Castillo, Y Zhang, L Bidaut, T Pan, R Komaki
Physics in Medicine & Biology 51 (4), 777, 2006
3052006
Implementation and evaluation of various demons deformable image registration algorithms on a GPU
X Gu, H Pan, Y Liang, R Castillo, D Yang, D Choi, E Castillo, A Majumdar, ...
Physics in Medicine & Biology 55 (1), 207, 2009
3012009
Four-dimensional deformable image registration using trajectory modeling
E Castillo, R Castillo, J Martinez, M Shenoy, T Guerrero
Physics in Medicine & Biology 55 (1), 305, 2009
2802009
Ventilation from four-dimensional computed tomography: density versus Jacobian methods
R Castillo, E Castillo, J Martinez, T Guerrero
Physics in Medicine & Biology 55 (16), 4661, 2010
2112010
Quantification of regional ventilation from treatment planning CT
T Guerrero, K Sanders, J Noyola-Martinez, E Castillo, Y Zhang, R Tapia, ...
International Journal of Radiation Oncology* Biology* Physics 62 (3), 630-634, 2005
2102005
A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive
R Castillo, E Castillo, D Fuentes, M Ahmad, AM Wood, MS Ludwig, ...
Physics in Medicine & Biology 58 (9), 2861, 2013
1382013
Use of 4-dimensional computed tomography-based ventilation imaging to correlate lung dose and function with clinical outcomes
Y Vinogradskiy, R Castillo, E Castillo, SL Tucker, Z Liao, T Guerrero, ...
International Journal of Radiation Oncology* Biology* Physics 86 (2), 366-371, 2013
1272013
Hyperpolarized 3He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer
L Mathew, A Wheatley, R Castillo, E Castillo, G Rodrigues, T Guerrero, ...
Academic radiology 19 (12), 1546-1553, 2012
1012012
Point cloud segmentation and denoising via constrained nonlinear least squares normal estimates
E Castillo, J Liang, H Zhao
Innovations for Shape Analysis: Models and Algorithms, 283-299, 2013
912013
Association of anticoagulation dose and survival in hospitalized COVID‐19 patients: a retrospective propensity score‐weighted analysis
F Ionescu, I Jaiyesimi, I Petrescu, PR Lawler, E Castillo, ...
European journal of haematology 106 (2), 165-174, 2021
832021
Use of weekly 4DCT‐based ventilation maps to quantify changes in lung function for patients undergoing radiation therapy
YY Vinogradskiy, R Castillo, E Castillo, A Chandler, MK Martel, ...
Medical physics 39 (1), 289-298, 2012
812012
Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data
D Brennan, L Schubert, Q Diot, R Castillo, E Castillo, T Guerrero, ...
International Journal of Radiation Oncology* Biology* Physics 92 (2), 423-429, 2015
772015
Evaluating the toxicity reduction with computed tomographic ventilation functional avoidance radiation therapy
AM Faught, Y Miyasaka, N Kadoya, R Castillo, E Castillo, Y Vinogradskiy, ...
International Journal of Radiation Oncology* Biology* Physics 99 (2), 325-333, 2017
732017
Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis
R Castillo, E Castillo, M McCurdy, DR Gomez, AM Block, D Bergsma, ...
Physics in Medicine & Biology 57 (7), 1855, 2012
672012
Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study
Y Vinogradskiy, PJ Koo, R Castillo, E Castillo, T Guerrero, LE Gaspar, ...
International Journal of Radiation Oncology* Biology* Physics 89 (1), 199-205, 2014
662014
Quality assurance assessment of diagnostic and radiation therapy–simulation CT image registration for head and neck radiation therapy: anatomic region of interest–based …
ASR Mohamed, MN Ruangskul, MJ Awan, CA Baron, J Kalpathy-Cramer, ...
Radiology 274 (3), 752-763, 2015
652015
Evaluating which dose-function metrics are most critical for functional-guided radiation therapy
AM Faught, T Yamamoto, R Castillo, E Castillo, J Zhang, M Miften, ...
International Journal of Radiation Oncology* Biology* Physics 99 (1), 202-209, 2017
582017
Regional lung function profiles of stage I and III lung cancer patients: an evaluation for functional avoidance radiation therapy
Y Vinogradskiy, L Schubert, Q Diot, T Waxweiller, P Koo, R Castillo, ...
International Journal of Radiation Oncology* Biology* Physics 95 (4), 1273-1280, 2016
522016
Pre-radiotherapy FDG PET predicts radiation pneumonitis in lung cancer
R Castillo, N Pham, S Ansari, D Meshkov, S Castillo, M Li, A Olanrewaju, ...
Radiation Oncology 9, 1-10, 2014
522014
The system can't perform the operation now. Try again later.
Articles 1–20