Thrombolysis with alteplase 3 to 4.5 hours after acute ischemic stroke W Hacke, M Kaste, E Bluhmki, M Brozman, A Dávalos, D Guidetti, ... New England journal of medicine 359 (13), 1317-1329, 2008 | 8576 | 2008 |
Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery JW Moses, MB Leon, JJ Popma, PJ Fitzgerald, DR Holmes, ... New England Journal of Medicine 349 (14), 1315-1323, 2003 | 5899 | 2003 |
Protected carotid-artery stenting versus endarterectomy in high-risk patients JS Yadav, MH Wholey, RE Kuntz, P Fayad, BT Katzen, GJ Mishkel, ... New England Journal of Medicine 351 (15), 1493-1501, 2004 | 3196 | 2004 |
A clinical trial comparing three antithrombotic-drug regimens after coronary-artery stenting MB Leon, DS Baim, JJ Popma, PC Gordon, DE Cutlip, KKL Ho, ... New England Journal of Medicine 339 (23), 1665-1671, 1998 | 2380 | 1998 |
ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines)—executive summary: a report of the American College of Cardiology/American … SC Smith Jr, JT Dove, AK Jacobs, JW Kennedy, D Kereiakes, MJ Kern, ... Circulation 103 (24), 3019-3041, 2001 | 1490 | 2001 |
Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials DE Cutlip, DS Baim, KKL Ho, JJ Popma, AJ Lansky, DJ Cohen, ... Circulation 103 (15), 1967-1971, 2001 | 1210 | 2001 |
Immediate and late clinical outcomes of carotid artery stenting in patients with symptomatic and asymptomatic carotid artery stenosis: a 5-year prospective analysis GS Roubin, G New, SS Iyer, JJ Vitek, N Al-Mubarak, MW Liu, J Yadav, ... Circulation 103 (4), 532-537, 2001 | 1036 | 2001 |
Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting MB Leon, PS Teirstein, JW Moses, P Tripuraneni, AJ Lansky, S Jani, ... New England Journal of Medicine 344 (4), 250-256, 2001 | 925 | 2001 |
Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts DS Baim, D Wahr, B George, MB Leon, J Greenberg, DE Cutlip, U Kaya, ... Circulation 105 (11), 1285-1290, 2002 | 921 | 2002 |
The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS) E Schampaert, EA Cohen, M Schlüter, F Reeves, M Traboulsi, LM Title, ... Journal of the American College of Cardiology 43 (6), 1110-1115, 2004 | 821 | 2004 |
Analysis of 1-year clinical outcomes in the SIRIUS trial: a randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis DR Holmes Jr, MB Leon, JW Moses, JJ Popma, D Cutlip, PJ Fitzgerald, ... Circulation 109 (5), 634-640, 2004 | 817 | 2004 |
Incidence and treatment of'no-reflow'after percutaneous coronary intervention. RN Piana, GY Paik, M Moscucci, DJ Cohen, CM Gibson, AD Kugelmass, ... circulation 89 (6), 2514-2518, 1994 | 806 | 1994 |
Myonecrosis after revascularization procedures RM Califf, AE Abdelmeguid, RE Kuntz, JJ Popma, CJ Davidson, ... Journal of the American College of Cardiology 31 (2), 241-251, 1998 | 729 | 1998 |
Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomy RE Kuntz, CM Gibson, M Nobuyoshi, DS Baim Journal of the American College of Cardiology 21 (1), 15-25, 1993 | 692 | 1993 |
Phase 1/2 placebo-controlled, double-blind, dose-escalating trial of myocardial vascular endothelial growth factor 2 gene transfer by catheter delivery in patients with chronic … DW Losordo, PR Vale, RC Hendel, CE Milliken, FD Fortuin, N Cummings, ... Circulation 105 (17), 2012-2018, 2002 | 657 | 2002 |
Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical … J Fajadet, W Wijns, GJ Laarman, KH Kuck, J Ormiston, T Münzel, ... Circulation 114 (8), 798-806, 2006 | 608 | 2006 |
Impact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo … I Moussa, MB Leon, DS Baim, WW O’Neill, JJ Popma, M Buchbinder, ... Circulation 109 (19), 2273-2278, 2004 | 596 | 2004 |
Clinical restenosis after coronary stenting: perspectives from multicenter clinical trials DE Cutlip, MS Chauhan, DS Baim, KKL Ho, JJ Popma, JP Carrozza, ... Journal of the American College of Cardiology 40 (12), 2082-2089, 2002 | 594 | 2002 |
Final results of the can routine ultrasound influence stent expansion (CRUISE) study PJ Fitzgerald, A Oshima, M Hayase, JA Metz, SR Bailey, DS Baim, ... Circulation 102 (5), 523-530, 2000 | 589 | 2000 |
The relative importance of arterial remodeling compared with intimal hyperplasia in lumen renarrowing after balloon angioplasty. A study in the normal rabbit and the … MJ Post, C Borst, RE Kuntz Circulation 89 (6), 2816-2821, 1994 | 551 | 1994 |