Follow
Dete van Eeden
Dete van Eeden
Senior lecturer/Medical Physicist, University of the Free State, Bloemfontein, South Africa
Verified email at ufs.ac.za
Title
Cited by
Cited by
Year
EGS_cbct: Simulation of a fan beam CT and RMI phantom for measured HU verification
D van Eeden, F du Plessis
Physica Medica 32 (10), 1375-1380, 2016
82016
Characterization of Nylon-12 as a water-equivalent solid phantom material for dosimetric measurements in therapeutic photon and electron beams
N Ade, D Van Eeden, FCP du Plessis
Applied Radiation and Isotopes 155, 108919, 2020
62020
The relation between XR-QA2 and RT-QA2 GafchromicTM film optical density and absorbed dose in water produced by radionuclides
MM Joubert, D van Eeden, FCP du Plessis
Biomedical Physics & Engineering Express 7 (3), 035001, 2021
22021
Dose shadowing and prosthesis involvement for megavoltage photon in vivo diode dosimetry
N Ade, D Van Eeden, FCP Du Plessis
Journal of Medical Physics 44 (4), 254-262, 2019
22019
Set-up error validation with EPID images: measurements vs Egs_cbct simulation
D van Eeden, FHJ O’Reilly, FCP du Plessis
Reports of Practical Oncology and Radiotherapy 24 (6), 614-623, 2019
22019
Validation of Monte Carlo-based calculations for megavolt electron beams for IORT and FLASH-IORT
GL Lazarus, D van Eeden, FCP du Plessis
Heliyon 8 (9), 2022
12022
Practical Dosimetry Considerations for Small MLC-Shaped Electron Fields at 60 cm SSD
D Van Eeden, KN Sachse, FCP Du Plessis
Journal of Biomedical Physics & Engineering 12 (1), 101, 2022
12022
Multi-energy computed tomography breast imaging with Monte Carlo simulations: Contrast-to-noise-based image weighting
D Van Eeden, FCP Du Plessis
Journal of Medical Physics 44 (2), 106-112, 2019
12019
Hybrid Monte Carlo source model: Advantages and deficiencies
D Van Eeden, FCP Du Plessis
Polish Journal of Medical Physics and Engineering 24 (2), 65-74, 2018
12018
Development of a particle source model for a synergy linear accelerator to be used in Monte Carlo radiation dose calculations for cancer therapy
D Van Eeden
University of the Free State, 2014
12014
P-type QEDTM in vivo dosimeter sensitivity in 6 MV beams: Effects of backscattering media and beam accessories
D van Eeden, FCP du Plessis
Radiation Physics and Chemistry 215, 111334, 2024
2024
Evaluation of artificial neural network designs for Gafchromic™ film calibration with Tc-99m and digital photos
D van Eeden, MM Joubert, FCP du Plessis
Applied Radiation and Isotopes 187, 110311, 2022
2022
Measured, Calculated and Monte Carlo Simulated Dose Distributions in a Unique Gold Applicator Loaded with I-125 Seeds
C Trauernicht, E Hering, F Du Plessis, G Maree, D Van Eeden
MEDICAL PHYSICS 47 (6), E812-E813, 2022
2022
Photon beam dose enhancement in AuNP AC tumour through energy moderation of a 6 MeV electron beam: A Monte Carlo study
D van Eeden, S Mutsakanyi, FCP du Plessis
Radiation Physics and Chemistry 192, 109925, 2022
2022
Could a virtual bowtie filter improve image quality? A breast simulation study
D van Eeden, FC du Plessis
Computer Methods in Biomechanics and Biomedical Engineering: Imaging …, 2020
2020
Validation of a Lévy electron energy straggling model for an Elekta Synergy® linear accelerator
D van Eeden, KN Sachse, FCP du Plessis
Applied Radiation and Isotopes 164, 109244, 2020
2020
Feasibility of tissue differentiation with multi-energy computed tomography: a Monte Carlo breast phantom study
D Van Eeden
University of the Free State, 2017
2017
O55. Feasibility of tissue differentiation with multi-energy computed tomography: A Monte Carlo study
D van Eeden, FCP du Plessis
Physica Medica: European Journal of Medical Physics 32, 159, 2016
2016
Computed tomography simulation to be used in EGSnrc Monte Carlo simulations
D van Eeden, FCP Du Plessis
Physica Medica: European Journal of Medical Physics 31, S14, 2015
2015
The system can't perform the operation now. Try again later.
Articles 1–19