Follow
Charles Kirkby
Charles Kirkby
Senior Medical Physicist, Jack Ady Cancer Centre, University of Calgary
Verified email at albertahealthservices.ca
Title
Cited by
Cited by
Year
Patient dosimetry for hybrid MRI‐radiotherapy systems
C Kirkby, T Stanescu, S Rathee, M Carlone, B Murray, BG Fallone
Medical physics 35 (3), 1019-1027, 2008
1802008
Lung dosimetry in a linac‐MRI radiotherapy unit with a longitudinal magnetic field
C Kirkby, B Murray, S Rathee, BG Fallone
Medical physics 37 (9), 4722-4732, 2010
1202010
Rapid MCNP simulation of DNA double strand break (DSB) relative biological effectiveness (RBE) for photons, neutrons, and light ions
RD Stewart, SW Streitmatter, DC Argento, C Kirkby, JT Goorley, G Moffitt, ...
Physics in Medicine & Biology 60 (21), 8249, 2015
1092015
Is low dose radiation therapy a potential treatment for COVID-19 pneumonia?
C Kirkby, M Mackenzie
Radiotherapy and Oncology 147, 221, 2020
1082020
Consequences of the spectral response of an a‐Si EPID and implications for dosimetric calibration
C Kirkby, R Sloboda
Medical physics 32 (8), 2649-2658, 2005
1042005
Comprehensive Monte Carlo calculation of the point spread function for a commercial‐Si EPID
C Kirkby, R Sloboda
Medical physics 32 (4), 1115-1127, 2005
872005
Skin dose in longitudinal and transverse linac‐MRIs using Monte Carlo and realistic 3D MRI field models
A Keyvanloo, B Burke, B Warkentin, T Tadic, S Rathee, C Kirkby, ...
Medical physics 39 (10), 6509-6521, 2012
832012
TU‐C‐M100F‐01: development of a linac‐MRI system for real‐time ART
B Fallone, M Carlone, B Murray, S Rathee, T Stanescu, S Steciw, ...
Medical Physics 34 (6Part17), 2547-2547, 2007
722007
Electron distribution function in laser heated plasmas
E Fourkal, VY Bychenkov, W Rozmus, R Sydora, C Kirkby, CE Capjack, ...
Physics of Plasmas 8 (2), 550-556, 2001
642001
Targeting mitochondria in cancer cells using gold nanoparticle‐enhanced radiotherapy: A Monte Carlo study
C Kirkby, E Ghasroddashti
Medical physics 42 (2), 1119-1128, 2015
582015
A method for converting dose-to-medium to dose-to-tissue in Monte Carlo studies of gold nanoparticle-enhanced radiotherapy
B Koger, C Kirkby
Physics in Medicine & Biology 61 (5), 2014, 2016
402016
RBE of kV CBCT radiation determined by Monte Carlo DNA damage simulations
C Kirkby, E Ghasroddashti, Y Poirier, M Tambasco, RD Stewart
Physics in Medicine & Biology 58 (16), 5693, 2013
402013
Magnetic field effects on the energy deposition spectra of MV photon radiation
C Kirkby, T Stanescu, BG Fallone
Physics in Medicine & Biology 54 (2), 243, 2008
392008
A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field
C Kirkby, C Field, M MacKenzie, A Syme, BG Fallone
Physics in Medicine & Biology 52 (12), 3563, 2007
392007
Relative biological damage and electron fluence in and out of a 6 MV photon field
A Syme, C Kirkby, R Mirzayans, M MacKenzie, C Field, BG Fallone
Physics in Medicine & Biology 54 (21), 6623, 2009
382009
An integrated 6 MV linear accelerator model from electron gun to dose in a water tank
J St. Aubin, S Steciw, C Kirkby, BG Fallone
Medical Physics 37 (5), 2279-2288, 2010
372010
Monte Carlo calculation of helical tomotherapy dose delivery
YL Zhao, M Mackenzie, C Kirkby, BG Fallone
Medical physics 35 (8), 3491-3500, 2008
362008
Liver irradiation causes distal bystander effects in the rat brain and affects animal behaviour
A Kovalchuk, R Mychasiuk, A Muhammad, S Hossain, S Ilnytskyy, ...
Oncotarget 7 (4), 4385, 2016
342016
Monte Carlo evaluation of a treatment planning system for helical tomotherapy in an anthropomorphic heterogeneous phantom and for clinical treatment plans
YL Zhao, M Mackenzie, C Kirkby, BG Fallone
Medical physics 35 (12), 5366-5374, 2008
302008
Monte Carlo investigation of single cell beta dosimetry for intraperitoneal radionuclide therapy
AM Syme, C Kirkby, TA Riauka, BG Fallone, SA McQuarrie
Physics in Medicine & Biology 49 (10), 1959, 2004
292004
The system can't perform the operation now. Try again later.
Articles 1–20