Follow
Quentin Goossens
Title
Cited by
Cited by
Year
Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study
Q Goossens, S Leuridan, P Henyš, J Roosen, L Pastrav, M Mulier, ...
Medical Engineering & Physics 49, 28-38, 2017
262017
Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study
Q Goossens, L Pastrav, J Roosen, M Mulier, W Desmet, J Vander Sloten, ...
Journal of Orthopaedic Research® 39 (6), 1164-1173, 2021
232021
Determination of replicate composite bone material properties using modal analysis
S Leuridan, Q Goossens, L Pastrav, J Roosen, M Mulier, K Denis, ...
Journal of the mechanical behavior of biomedical materials 66, 12-18, 2017
182017
Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study
S Leuridan, Q Goossens, T Vander Sloten, K De Landsheer, H Delport, ...
Medical Engineering & Physics 49, 109-120, 2017
152017
Modal frequency and shape curvature as a measure of implant fixation: A computer study on the acetabular cup
P Henyš, S Leuridan, Q Goossens, M Mulier, L Pastrav, W Desmet, ...
Medical Engineering & Physics 60, 30-38, 2018
122018
A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body …
S Leuridan, Q Goossens, J Roosen, L Pastrav, K Denis, M Mulier, ...
Clinical Biomechanics 42, 70-78, 2017
102017
Development of an instrument to assess the stability of cementless femoral implants using vibration analysis during total hip arthroplasty
S Leuridan, Q Goossens, LC Pastrav, M Mulier, W Desmet, ...
IEEE Journal of Translational Engineering in Health and Medicine 9, 1-10, 2021
72021
The use of a vibro-acoustic based method to determine the composite material properties of a replicate clavicle bone model
Q Goossens, S Vancleef, S Leuridan, LC Pastrav, M Mulier, W Desmet, ...
Journal of Functional Biomaterials 11 (4), 69, 2020
72020
Influence of artificial soft tissue on intra-operative vibration analysis method for primary fixation monitoring in cementless total hip arthroplasty
G Athanassoulis Makris, L Pastrav, Q Goossens, M Timmermans, ...
Applied Sciences 12 (8), 4027, 2022
32022
Two Different Methods to Measure the Stability of Acetabular Implants: A Comparison Using Artificial Acetabular Models
Q Goossens, LC Pastrav, M Mulier, W Desmet, J Vander Sloten, K Denis
Sensors 20 (1), 254, 2020
32020
Knee acoustic emissions as a noninvasive biomarker of articular health in patients with juvenile idiopathic arthritis: a clinical validation in an extended study population
Q Goossens, M Locsin, S Gharehbaghi, P Brito, E Moise, LA Ponder, ...
Pediatric Rheumatology 21 (1), 59, 2023
22023
A nondestructive method to verify the glenosphere-baseplate assembly in reverse shoulder arthroplasty
S Leuridan, Q Goossens, L Pastrav, A Van Tongel, L De Wilde, P Debeer, ...
Journal of Shoulder and Elbow Surgery 25 (6), e156-e165, 2016
22016
Monitoring of the Reamer Seating using Acoustic Information
Q Goossens, S Leuridan, J Roosen, L Pastrav, M Mulier, W Desmet, ...
Congress of the European Society of Biomechanics, Date: 2015/07/05-2015/07 …, 2015
22015
KneeMS: A Low-Cost Wireless Wearable System to Monitor Knee Acoustic Emissions
M Nikbakht, Q Goossens, GC Ozmen, M Bibidakis, DJ Lin, OT Inan
2023 IEEE 19th International Conference on Body Sensor Networks (BSN), 1-4, 2023
12023
Mid-activity and at-home wearable bioimpedance elucidates an interpretable digital biomarker of muscle fatigue
GC Ozmen, S Mabrouk, C Nichols, J Berkebile, Q Goossens, AH Gazi, ...
IEEE Transactions on Biomedical Engineering, 2023
12023
Development of a femoral implant instrument to assess primary stability using vibrational analysis
Q Goossens, S Leuridan, L Pastrav, J Roosen, M Mulier, W Desmet, ...
25th Congress of the European Society of Biomechanics (ESB 2019), Date: 2019 …, 2019
12019
An acoustic measurement method to assess acetabular implant stability in cementless total hip replacement
Q Goossens, L Pastrav, J Roosen, M Mulier, W Desmet, J Vander Sloten, ...
ICSV26 Proceedings, 2019
12019
Comparison of cementless THA stem insertion using the Woodpecker versus hammer blows by strain and vibrational measurements: an in vitro study
Q Goossens, S Leuridan, L Pastrav, M Mulier, W Desmet, K Denis, ...
Orthopaedic Proceedings 99 (SUPP_3), 141-141, 2017
12017
The use of vibro-acoustic information to assess acetabular cup seating during THA: an in vitro study
Q Goossens, S Leuridan, P Henyš, J Roosen, L Pastrav, M Mulier, ...
Proceedings of the International Conference on Noise and Vibration …, 2016
12016
Vibration-based Fixation Assessment of Tibial TKA Components: A Numerical and Experimental In Vitro Study
T Vander Sloten, K De Landsheer, S Leuridan, Q Goossens, LC Pastrav, ...
EORS (European Orthopaedic Research Society), Date: 2014/07/02-2014/07/04 …, 2014
12014
The system can't perform the operation now. Try again later.
Articles 1–20