Increased work of breathing due to tracheomalacia in neonates
CC Gunatilaka, NS Higano, EB Hysinger, DB Gandhi, RJ Fleck, AD Hahn, ...
Annals of the American Thoracic Society 17 (10), 1247-1256, 2020
372020
Magnetic resonance elastography‐derived stiffness of the kidneys and its correlation with water perfusion
D Gandhi, P Kalra, B Raterman, X Mo, H Dong, A Kolipaka
NMR in Biomedicine 33 (4), e4237, 2020
262020
Magnetic Resonance Elastography of kidneys: SE‐EPI MRE reproducibility and its comparison to GRE MRE
D Gandhi, P Kalra, B Raterman, X Mo, H Dong, A Kolipaka
NMR in Biomedicine 32 (11), e4141, 2019
202019
Association between liver diffusion-weighted imaging apparent diffusion coefficient values and other measures of liver disease in pediatric autoimmune liver disease patients
N Abu Ata, JR Dillman, DB Gandhi, JA Dudley, AT Trout, AG Miethke
Abdominal Radiology 46, 197-204, 2021
102021
Multiparametric quantitative renal MRI in children and young adults: comparison between healthy individuals and patients with chronic kidney disease
JR Dillman, SW Benoit, DB Gandhi, AT Trout, JA Tkach, K VandenHeuvel, ...
Abdominal Radiology 47 (5), 1840-1852, 2022
92022
Neonates with tracheomalacia generate auto-positive end-expiratory pressure via glottis closure
CC Gunatilaka, EB Hysinger, A Schuh, DB Gandhi, NS Higano, Q Xiao, ...
Chest 160 (6), 2168-2177, 2021
62021
Assessment of agreement between manual and automated processing of liver MR elastography for shear stiffness estimation in children and young adults with autoimmune liver disease
DB Gandhi, A Pednekar, AB Braimah, J Dudley, JA Tkach, AT Trout, ...
Abdominal Radiology 46, 3927-3934, 2021
62021
Quantitative evaluation of subglottic stenosis using ultrashort echo time MRI in a rabbit model
DB Gandhi, A Rice, CC Gunatilaka, NS Higano, RJ Fleck, A de Alarcon, ...
The Laryngoscope 131 (6), E1971-E1979, 2021
62021
Velocity-encoded phase-contrast MRI for measuring mesenteric blood flow in patients with newly diagnosed small-bowel Crohn disease
NA Ata, JR Dillman, D Gandhi, JA Dudley, AT Trout, R Imbus, AJ Towbin, ...
American Journal of Roentgenology 219 (1), 132-141, 2022
52022
Associations between MRI T1 mapping, liver stiffness, quantitative MRCP, and laboratory biomarkers in children and young adults with autoimmune liver disease
N Mahalingam, AT Trout, DB Gandhi, RD Sahay, R Singh, AG Miethke, ...
Abdominal Radiology 47 (2), 672-683, 2022
42022
Relationship between magnetic resonance imaging spleen T1 relaxation and other radiologic and clinical biomarkers of liver fibrosis in children and young adults with autoimmune …
JR Dillman, JA Tkach, D Gandhi, R Singh, AG Miethke, A Jayaswal, ...
Abdominal Radiology 45, 3709-3715, 2020
42020
Virtual bronchoscopy of neonatal airway malacia via high-resolution, respiratory-gated magnetic resonance imaging
NS Higano, DB Gandhi, Q Xiao, CC Gunatilaka, EB Hysinger, RJ Fleck, ...
American Journal of Respiratory and Critical Care Medicine 206 (5), e42-e43, 2022
32022
Obesity blunts amelioration of cardiac hypertrophy and fibrosis by human mesenchymal stem/stromal cell-derived extracellular vesicles
S Hong, W Huang, X Zhu, H Tang, JD Krier, L Xing, B Lu, D Gandhi, ...
American Journal of Physiology-Heart and Circulatory Physiology 325 (1 …, 2023
22023
Performance of C‐SENSE Accelerated Rapid Liver Shear Stiffness Measurement Using Displacement Wave Polarity‐Inversion Motion Encoding: An Evaluation Study
A Pednekar, D Gandhi, H Wang, JA Tkach, AT Trout, JR Dillman
Journal of Magnetic Resonance Imaging 56 (3), 754-765, 2022
22022
Agreement Between Automated and Clinically Reported Manual ROI–Based MR Elastography Liver Stiffness Measurements in Children and Young Adults
JR Dillman, MD Franck, D Gandhi, AS Pednekar, JA Tkach, AT Trout
American Journal of Roentgenology 218 (1), 163-164, 2022
22022
Training and Comparison of nnU-Net and DeepMedic Methods for Autosegmentation of Pediatric Brain Tumors
A Vossough, N Khalili, AM Familiar, D Gandhi, K Viswanathan, W Tu, ...
arXiv preprint arXiv:2401.08404, 2024
12024
Evaluation of Renal Fibrosis Using Magnetization Transfer Imaging at 1.5 T and 3T in a Porcine Model of Renal Artery Stenosis
DB Gandhi, M Al Saeedi, JD Krier, K Jiang, JF Glockner, LO Lerman
Journal of Clinical Medicine 12 (8), 2956, 2023
12023
Predicting tracheal work of breathing in neonates based on radiological and pulmonary measurements
CC Gunatilaka, EB Hysinger, A Schuh, Q Xiao, DB Gandhi, NS Higano, ...
Journal of Applied Physiology 133 (4), 893-901, 2022
12022
Neonates with tracheomalacia generate auto-peep via glottis closure measured by MRI-based computational fluid dynamics
CC Gunatilaka, AJ Bates, EB Hysinger, A Schuh, DB Gandhi, NS Higano, ...
TP72. TP072 BRONCHOPULMONARY DYSPLASIA, A3312-A3312, 2021
12021
The Brain Tumor Segmentation in Pediatrics (BraTS-PEDs) Challenge: Focus on Pediatrics (CBTN-CONNECT-DIPGR-ASNR-MICCAI BraTS-PEDs)
AF Kazerooni, N Khalili, D Gandhi, X Liu, Z Jiang, SM Anwar, J Albrecht, ...
arXiv preprint arXiv:2404.15009, 2024
2024