Follow
Tobias Reinecke
Tobias Reinecke
IONICON Analytik GmbH
Verified email at ionicon.com - Homepage
Title
Cited by
Cited by
Year
Implementation of a flexible, open-source platform for ion mobility spectrometry
T Reinecke, BH Clowers
HardwareX 4, e00030, 2018
552018
Ion multiplexing: Maximizing throughput and signal to noise ratio for ion mobility spectrometry
T Reinecke, CN Naylor, BH Clowers
TrAC Trends in Analytical Chemistry 116, 340-345, 2019
382019
Validation of calibration parameters for trapped ion mobility spectrometry
CN Naylor, T Reinecke, ME Ridgeway, MA Park, BH Clowers
Journal of the American Society for Mass Spectrometry 30 (10), 2152-2162, 2019
342019
Compact unfocused antenna setup for X-band free-space dielectric measurements based on line-network-network calibration method
C Orlob, T Reinecke, E Denicke, B Geck, I Rolfes
IEEE Transactions on Instrumentation and Measurement 62 (7), 1982-1989, 2013
342013
Design and evaluation of split-ring resonators for aptamer-based biosensors
T Reinecke, JG Walter, T Kobelt, A Ahrens, T Scheper, S Zimmermann
Journal of Sensors and Sensor Systems 7 (1), 101-111, 2018
322018
A compact high resolution electrospray ionization ion mobility spectrometer
T Reinecke, AT Kirk, A Ahrens, CR Raddatz, C Thoben, S Zimmermann
Talanta 150, 1-6, 2016
312016
Increased ion throughput using tristate ion-gate multiplexing
P Kwantwi-Barima, T Reinecke, BH Clowers
Analyst 144 (22), 6660-6670, 2019
272019
A compact high-resolution X-ray ion mobility spectrometer
T Reinecke, AT Kirk, A Heptner, D Niebuhr, S Böttger, S Zimmermann
Review of Scientific Instruments 87 (5), 2016
252016
Determination of gas-phase ion mobility coefficients using voltage sweep multiplexing
T Reinecke, AL Davis, BH Clowers
Journal of The American Society for Mass Spectrometry 30 (6), 977-986, 2019
222019
Continuous noninvasive monitoring of cell growth in disposable bioreactors
T Reinecke, P Biechele, M Sobocinski, H Suhr, K Bakes, D Solle, ...
Sensors and Actuators B: Chemical 251, 1009-1017, 2017
212017
Assessing the impact of drift gas polarizability in polyatomic ion mobility experiments
CN Naylor, T Reinecke, BH Clowers
Analytical chemistry 92 (6), 4226-4234, 2020
192020
Ion mobility spectrometer with orthogonal X-ray source for increased sensitivity
E Bunert, T Reinecke, AT Kirk, A Bohnhorst, S Zimmermann
Talanta 185, 537-541, 2018
192018
Shutterless ion mobility spectrometer with fast pulsed electron source
E Bunert, A Heptner, T Reinecke, AT Kirk, S Zimmermann
Review of Scientific Instruments 88 (2), 2017
192017
Low-cost sensor system for non-invasive monitoring of cell growth in disposable bioreactors
T Reinecke, P Biechele, V Schulte, T Scheper, S Zimmermann
Procedia Engineering 120, 548-551, 2015
172015
X-ray ionization differential ion mobility spectrometry
A Kuklya, T Reinecke, F Uteschil, K Kerpen, S Zimmermann, U Telgheder
Talanta 162, 159-166, 2017
162017
Optimized reconstruction techniques for multiplexed dual-gate ion mobility mass spectrometry experiments
AL Davis, T Reinecke, KA Morrison, BH Clowers
Analytical chemistry 91 (2), 1432-1440, 2018
122018
Quantification of edema in human brain tissue by determination of electromagnetic parameters
T Reinecke, L Hagemeier, V Schulte, M Klintschar, S Zimmermann
SENSORS, 2013 IEEE, 1-4, 2013
122013
Open-ended coaxial probe for the quantification of edema in human brain tissue
T Reinecke, L Hagemeier, H Spehlbrink, S Guenther, M Klintschar, ...
Sensors and Actuators B: Chemical 204, 763-769, 2014
112014
Improving the analytical performance of ion mobility spectrometer using a non-radioactive electron source
A Heptner, N Angerstein, T Reinecke, E Bunert, AT Kirk, I Niedzwiecki, ...
International Journal for Ion Mobility Spectrometry 19, 175-182, 2016
102016
A gated atmospheric pressure drift tube ion mobility spectrometer–time-of-flight mass spectrometer
A Heptner, T Reinecke, J Langejuergen, S Zimmermann
Journal of Chromatography A 1356, 241-248, 2014
102014
The system can't perform the operation now. Try again later.
Articles 1–20