Seguir
Araceli Gago-Arias
Araceli Gago-Arias
Fundación Instituto de Investigación Sanitaria de Santiago de Compostela
Dirección de correo verificada de sergas.es
Título
Citado por
Citado por
Año
Structural and functional identification of vasculogenic mimicry in vitro
D Racordon, A Valdivia, G Mingo, R Erices, R Aravena, F Santoro, ...
Scientific Reports 7 (1), 6985, 2017
532017
Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: machine‐specific, plan‐class, and clinical fields
A Gago‐Arias, R Rodríguez‐Romero, P Sánchez‐Rubio, ...
Medical physics 39 (4), 1964-1970, 2012
312012
Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays
A Gago-Arias, L Brualla-González, DM González-Castaño, F Gómez, ...
Physics in Medicine & Biology 57 (7), 2005, 2012
312012
Correction factors for ionization chamber dosimetry in CyberKnife: Machine‐specific, plan‐class, and clinical fields
A Gago‐Arias, E Antolín, F Fayos‐Ferrer, R Simón, ...
Medical physics 40 (1), 011721, 2013
222013
A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests
L Brualla-González, F Gómez, A Vicedo, DM González-Castaño, ...
Physics in Medicine & Biology 57 (16), 5221, 2012
162012
A convolution model for obtaining the response of an ionization chamber in static non standard fields
DM González‐Castaño, LB González, MA Gago‐Arias, J Pardo‐Montero, ...
Medical Physics 39 (1), 482-491, 2012
162012
A model of indirect cell death caused by tumor vascular damage after high-dose radiotherapy
P Rodríguez-Barbeito, P Diaz-Botana, A Gago-Arias, M Feijoo, S Neira, ...
Cancer Research 79 (23), 6044-6053, 2019
142019
Impact of different biologically-adapted radiotherapy strategies on tumor control evaluated with a tumor response model
A Gago-Arias, B Sánchez-Nieto, I Espinoza, CP Karger, J Pardo-Montero
PLoS One 13 (4), e0196310, 2018
122018
Modelling radiation-induced cell death and tumour re-oxygenation: local versus global and instant versus delayed cell death
A Gago-Arias, P Aguiar, I Espinoza, B Sánchez-Nieto, J Pardo-Montero
Physics in Medicine & Biology 61 (3), 1204, 2016
112016
eIMRT: a web platform for the verification and optimization of radiation treatment plans
J Pena, DM González‐Castaño, F Gómez, A Gago‐Arias, ...
Journal of applied clinical medical physics 10 (3), 205-220, 2009
102009
eIMRT: a web platform for the verification and optimization of radiation treatment plans
J Pena, DM González‐Castaño, F Gómez, A Gago‐Arias, ...
Journal of applied clinical medical physics 10 (3), 205-220, 2009
102009
Quantification of internal dosimetry in PET patients: individualized Monte Carlo vs generic phantom‐based calculations
S Neira, J Guiu‐Souto, P Díaz‐Botana, P Pais, C Fernández, V Pubul, ...
Medical Physics 47 (9), 4574-4588, 2020
92020
Development of an alanine dosimetry system for radiation dose measurements in the radiotherapy range
A Gago-Arias, DM González-Castaño, F Gómez, E Peteiro, C Lodeiro, ...
Journal of Instrumentation 10 (08), T08004, 2015
82015
A kinetic model of continuous radiation damage to populations of cells: Comparison to the LQ model and application to molecular radiotherapy
S Neira, A Gago-Arias, J Guiu-Souto, J Pardo-Montero
Physics in Medicine & Biology 65 (24), 245015, 2020
72020
Evaluation of indirect damage and damage saturation effects in dose–response curves of hypofractionated radiotherapy of early-stage NSCLC and brain metastases
A Gago-Arias, S Neira, M Pombar, A Gómez-Caamaño, J Pardo-Montero
Radiotherapy and Oncology 161, 1-8, 2021
52021
Quantification of internal dosimetry in PET patients II: Individualized Monte Carlo‐based dosimetry for [18F] fluorocholine PET
S Neira, J Guiu‐Souto, P Pais, S Rodríguez Martínez de Llano, ...
Medical Physics 48 (9), 5448-5458, 2021
42021
A volumetric delta TCP tool to quantify treatment outcome effectiveness based on biological parameters and different dose distributions
D Fabri, A Gago-Arias, T Guerrero-Urbano, A Lopez-Medina, ...
World Congress on Medical Physics and Biomedical Engineering 2018: June 3-8 …, 2019
32019
Simulation of hypoxia PET-tracer uptake in tumours: Dependence of clinical uptake-values on transport parameters and arterial input function
I Paredes-Cisneros, CP Karger, P Caprile, D Nolte, I Espinoza, ...
Physica Medica 70, 109-117, 2020
22020
Erratum:“Correction factors for ionization chamber dosimetry in CyberKnife: Machine‐specific, plan‐class, and clinical fields”[Med. Phys. 40, 011721 (10pp.)(2013)]
A Gago‐Arias, E Antolín, F Fayos‐Ferrer, R Simón, ...
Medical Physics 40 (5), 057201, 2013
22013
Analysis of ionic mobilities in liquid isooctane with low dose radiotherapy pulsed photon beams
J Pardo-Montero, S Tegami, A Gago-Arias, DM González-Castaño, ...
Journal of Instrumentation 7 (09), P09008, 2012
22012
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20