Title
Cited by
Cited by
Year
Volume of fluid simulation of boiling two-phase flow in a vapor-venting microchannel
C Fang, M David, A Rogacs, K Goodson
Frontiers in Heat and Mass Transfer (FHMT) 1 (1), 2010
1872010
Server liquid cooling with chiller-less data center design to enable significant energy savings
M Iyengar, M David, P Parida, V Kamath, B Kochuparambil, D Graybill, ...
2012 28th annual IEEE semiconductor thermal measurement and management …, 2012
1422012
Hydraulic and thermal characteristics of a vapor venting two-phase microchannel heat exchanger
MP David, J Miler, JE Steinbrenner, Y Yang, M Touzelbaev, KE Goodson
International Journal of Heat and Mass Transfer 54 (25-26), 5504-5516, 2011
1192011
Experimental characterization of an energy efficient chiller-less data center test facility with warm water cooled servers
MP David, M Iyengar, P Parida, R Simons, M Schultz, M Gaynes, ...
2012 28th Annual IEEE Semiconductor Thermal Measurement and Management …, 2012
742012
Pump-enhanced, immersion-cooling of electronic component (s)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 9,357,675, 2016
722016
Data center cooling with an air-side economizer and liquid-cooled electronics rack (s)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,959,941, 2015
652015
Experimental and numerical dynamic investigation of an energy efficient liquid cooled chiller-less data center test facility
T Gao, M David, J Geer, R Schmidt, B Sammakia
Energy and buildings 91, 83-96, 2015
642015
Multi-fluid, two-phase immersion-cooling of electronic component (s)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,619,425, 2013
632013
Valve controlled, node-level vapor condensation for two-phase heat sink (s)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 9,069,532, 2015
622015
Wicking vapor-condenser facilitating immersion-cooling of electronic component (s)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,953,317, 2015
622015
Dynamically limiting energy consumed by cooling apparatus
TJ Chainer, MP David, MK Iyengar, PR Parida, RR Schmidt, MD Schultz
US Patent 9,043,035, 2015
612015
Influence of film thickness and cross-sectional geometry on hydrophilic microchannel condensation
C Fang, M David, F Wang, KE Goodson
International journal of multiphase flow 36 (8), 608-619, 2010
592010
Multi-rack assembly method with shared cooling unit
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,797,740, 2014
582014
Two-phase, water-based immersion-cooling apparatus with passive deionization
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,867,209, 2014
572014
Thermal transfer structures coupling electronics card (s) to coolant-cooled structure (s)
MP David, DP Graybill, MK Iyengar, V Kamath, BJ Kochuparambil, ...
US Patent 8,913,384, 2014
562014
Multi-rack assembly with shared cooling unit
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,817,474, 2014
542014
Dynamically limiting energy consumed by cooling apparatus
TJ Chainer, MP David, MK Iyengar, PR Parida, RR Schmidt, MD Schultz
US Patent 9,052,722, 2015
532015
Sectioned manifolds facilitating pumped immersion-cooling of electronic components
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,964,391, 2015
522015
Combined power and cooling rack supporting an electronics rack (S)
LA Campbell, RC Chu, MP David, MJ Ellsworth Jr, MK Iyengar, ...
US Patent 8,824,143, 2014
472014
Adiabatic and diabatic two-phase venting flow in a microchannel
MP David, JE Steinbrenner, J Miler, KE Goodson
International Journal of Multiphase Flow 37 (9), 1135-1146, 2011
472011