Follow
Mona  M. Gouda
Mona M. Gouda
Lecturer of radiation physics-Alex. University
Verified email at alexu.edu.eg - Homepage
Title
Cited by
Cited by
Year
Full-Energy peak efficiency of an NaI (Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance
AM El-Khatib, BA Salem, MS Badawi, MM Gouda, AA Thabet, MI Abbas
Chinese journal of Physics 55 (2), 478-489, 2017
352017
Analysis of particle size on mass dependent attenuation capability of bulk and nanoparticle PbO radiation shields
M Elsafi, MI Sayyed, AH Almuqrin, MM Gouda, AM El-Khatib
Results in Physics 26, 104458, 2021
332021
Efficiency of a cubic NaI (Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position
MI Abbas, MS Badawi, AA Thabet, YN Kopatch, IN Ruskov, ...
Applied Radiation and Isotopes 163, 109139, 2020
322020
Calibration of а single hexagonal NaI (Tl) detector using a new numerical method based on the efficiency transfer method
MI Abbas, MS Badawi, IN Ruskov, AM El-Khatib, DN Grozdanov, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015
312015
A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio
MS Badawi, I Ruskov, MM Gouda, AM El-Khatib, MF Alotiby, ...
Journal of Instrumentation 9 (07), P07030, 2014
312014
New algorithm for studying the effect of self attenuation factor on the efficiency of γ-rays detectors
MS Badawi, MM Gouda, SS Nafee, AM El-Khatib, EA El-Mallah
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2012
292012
New analytical approach to calibrate the co-axial HPGe detectors including correction for source matrix self-attenuation
MS Badawi, MM Gouda, SS Nafee, AM El-Khatib, EA El-Mallah
Applied Radiation and Isotopes 70 (12), 2661-2668, 2012
292012
Characterization of the efficiency of a cubic NaI detector with rectangular cavity for axially positioned sources
MS Badawi, S Noureddine, YN Kopatch, MI Abbas, IN Ruskov, ...
Journal of Instrumentation 15 (02), P02013, 2020
282020
Calibration of well-type NaI (Tl) detector using a point sources measured out the detector well at different axial distances
MM Gouda, MS Badawi, AM El-Khatib, MM Mohamed, AA Thabet, ...
Journal of Instrumentation 10 (03), P03022, 2015
272015
Mathematical method to calculate full-energy peak efficiency of detectors based on transfer technique
MM Gouda, A Hamzawy, MS Badawi, AM El-Khatib, AA Thabet, MI Abbas
Indian Journal of Physics 90, 201-210, 2016
232016
NaI cubic detector full-energy peak efficiency, including coincidence and self-absorption corrections for rectangular sources using analytical method
MI Abbas, M Elsafi, MM Gouda, M Abd-Elzaher, A Hamzawy, MS Badawi, ...
Journal of Radioanalytical and Nuclear Chemistry 327, 251-258, 2021
222021
New analytical approach to calibrate the NaI (Tl) detectors using spherical radioactive sources
AM El-Khatib, MM Gouda, MS Badawi, SS Nafee, EA El-Mallah
Radiation protection dosimetry 156 (1), 109-117, 2013
222013
Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software
AA Thabet, AD Dlabac, SI Jovanovic, MS Badawi, NN Mihaljevic, ...
Nuclear Technology and Radiation Protection 30 (1), 35-46, 2015
212015
Reduction of thrombogenicity of PVC-based sodium selective membrane electrodes using heparin-modified chitosan
IHA Badr, M Gouda, R Abdel-Sattar, HEM Sayour
Carbohydrate polymers 99, 783-790, 2014
212014
Effect of PbO-nanoparticles on dimethyl polysiloxane for use in radiation shielding applications
AM El-Khatib, MI Abbas, SI Hammoury, MM Gouda, K Zard, M Elsafi
Scientific Reports 12 (1), 15722, 2022
202022
Calibration of 4π NaI (Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software
MS Badawi, SI Jovanovic, AA Thabet, AM El-Khatib, AD Dlabac, ...
AIP Advances 7 (3), 2017
202017
Well-type NaI (Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity
AM El-Khatib, MS Badawi, AA Thabet, SI Jovanovic, MM Gouda, ...
Chinese Journal of Physics 54 (3), 338-346, 2016
192016
Geant4 tracks of NaI cubic detector peak efficiency, including coincidence summing correction for rectangular sources
M Elsafi, JS Alzahrani, MI Abbas, MM Gouda, AA Thabet, MS Badawi, ...
Nuclear Science and Engineering 195 (9), 1008-1016, 2021
162021
Computation of the full energy peak efficiency of an HPGE detector using a new compact simulation analytical approach for spherical sources
AM El-Khatib, MM Gouda, MS Badawi, SS Nafee, EA EL-Mallah
J. Eng. Sci. Technol 8, 623-638, 2013
162013
Assessment of γ-radiation shielding behavior of some mixed nature clays
AM El-khatib, MI Abbas, MI Sayyed, MU Khandaker, M Abd-Elzaher, ...
Radiation Physics and Chemistry 200, 110236, 2022
142022
The system can't perform the operation now. Try again later.
Articles 1–20