Apparatus and method for the determination of one or more neutron source characteristics
SL Bellinger, S Bolding, AN Caruso, B Cooper, JA Crow, J Currie, ...
US Patent 9,958,561, 2018
192018
A portable and wide energy range semiconductor-based neutron spectrometer
CB Hoshor, TM Oakes, ER Myers, BJ Rogers, JE Currie, SM Young, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015
172015
Novel design and development of a 3D-printed conformal superficial brachytherapy device for the treatment of non-melanoma skin cancer and keloids
J Chmura, A Erdman, E Ehler, J Lawrence, CT Wilke, B Rogers, ...
3D Printing in Medicine 5, 1-6, 2019
142019
Dosimetric characterization of a novel 90Y source for use in the conformal superficial brachytherapy device
B Rogers, J Lawrence, J Chmura, E Ehler, C Ferreira
Physica Medica 72, 52-59, 2020
62020
Apparatus and method for the determination of one or more neutron source characteristics
SL Bellinger, S Bolding, AN Caruso, B Cooper, JA Crow, J Currie, ...
US Patent 9,465,120, 2016
22016
Custom-Made Lead Shield for Select Permanent Implanted Cs-131 Brain Tumor Patients
AA Alshreef, DA Sterling, P Alaei, BJ Rogers, SR Drehmel, M Reynolds, ...
AAPM 65th Annual Meeting & Exhibition, 2023
2023
Gamos Monte Carlo Simulation to Calculate the Dose in Heterogeneities for Gammatile Implanted Brachytherapy
AA Alshreef, M Assalmi, BJ Rogers, CC Oare, C Ferreira
AAPM 65th Annual Meeting & Exhibition, 2023
2023
Validation of Gamos Monte Carlo Simulation for Cs-131 Brachytherapy Source in Water
AA Alshreef, BJ Rogers, CC Oare, C Ferreira
AAPM 65th Annual Meeting & Exhibition, 2023
2023
End-To-End Test for GammaTile Permanent Brain Implants
A Alshreef, B Rogers, P Alaei, P Bolan, C Ferreira
MEDICAL PHYSICS 49 (6), E821-E822, 2022
2022
Monte Carlo Simulation of the Permanent Implant-GammaTile
B Rogers, C Ferreira
MEDICAL PHYSICS 48 (6), 2021
2021
Multi-Source Conformal Superficial Brachytherapy: A Dose Escalation Study
B Rogers, J Lawrence, C Ferreira
MEDICAL PHYSICS 47 (6), E819-E819, 2020
2020
Development and Dosimetry of a Conformal Superficial Brachytherapy Device
BJ Rogers
University of Minnesota, 2020
2020
Impact of various irradiation conditions on delivered dose and cell viability for in vitro cell irradiation
BJ Rogers, J Lawrence, E Ehler, C Ferreira
Biomedical Physics & Engineering Express 5 (6), 067006, 2019
2019
Monte Carlo Simulation and Validation of a Novel Yttrium-90 Source for Use in a Conformal Superficial Brachytherapy Device
B Rogers, P Alaei, J Chmura, E Ehler, J Lawrence, C Wilke, C Ferreira
MEDICAL PHYSICS 46 (6), E495-E495, 2019
2019
Simulated Performance of a Multi-Source Conformal Superficial Brachytherapy Device
B Rogers, C Ferreira, J Lawrence, E Ehler, A Erdman
MEDICAL PHYSICS 45 (6), E355-E356, 2018
2018
The Evaluation of Dosimetric and Cancer Viability Difference Following In Vitro Irradiation
B Rogers, E Ehler, J Lawrence, C Ferreira
MEDICAL PHYSICS 44 (6), 2978-2978, 2017
2017
Modeling and design of a silicon-based high-pressure 3He replacement neutron detector
BJ Rogers
University of Missouri-Kansas City, 2015
2015
Novel Multidimensional Cross-Correlation Data Comparison Techniques for Spectroscopic Discernment in a Volumetrically Sensitive, Moderating Type Neutron Spectrometer
C Hoshor, S Young, B Rogers, J Currie, T Oakes, P Scott, W Miller, ...
APS March Meeting Abstracts 2014, W24. 010, 2014
2014
Neutron Scattering Dependence on Proximate Human Tissue from Fast Neutrons
B Rogers, C Hoshor, P Scott, J Crow, N Kramer, A Caruso
APS March Meeting Abstracts 2014, W24. 011, 2014
2014