A systematic study on the influence of carbon on the behavior of hard-to-ionize elements in inductively coupled plasma–mass spectrometry G Grindlay, J Mora, M de Loos-Vollebregt, F Vanhaecke Spectrochimica Acta Part B: Atomic Spectroscopy 86, 42-49, 2013 | 207 | 2013 |
Atomic spectrometry methods for wine analysis: A critical evaluation and discussion of recent applications G Grindlay, J Mora, L Gras, MTC de Loos-Vollebregt Analytica Chimica Acta 691 (1-2), 18-32, 2011 | 136 | 2011 |
Carbon-related matrix effects in inductively coupled plasma atomic emission spectrometry G Grindlay, L Gras, J Mora, MTC de Loos-Vollebregt Spectrochimica Acta Part B: Atomic Spectroscopy 63 (2), 234-243, 2008 | 121 | 2008 |
Application of a microwave-based desolvation system for multi-elemental analysis of wine by inductively coupled plasma based techniques G Grindlay, J Mora, S Maestre, L Gras Analytica chimica acta 629 (1-2), 24-37, 2008 | 48 | 2008 |
Determination of cadmium and lead in wine samples by means of dispersive liquid–liquid microextraction coupled to electrothermal atomic absorption spectrometry D Martínez, G Grindlay, L Gras, J Mora Journal of Food Composition and Analysis 67, 178-183, 2018 | 47 | 2018 |
Carbon-, sulfur-, and phosphorus-based charge transfer reactions in inductively coupled plasma–atomic emission spectrometry G Grindlay, L Gras, J Mora, MTC de Loos-Vollebregt Spectrochimica Acta Part B: Atomic Spectroscopy 115, 8-15, 2016 | 47 | 2016 |
Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry G Grindlay, J Mora, L Gras, MTC de Loos-Vollebregt Analytica Chimica Acta 652 (1-2), 154-160, 2009 | 47 | 2009 |
Introduction of organic solvent solutions into inductively coupled plasma-atomic emission spectrometry using a microwave assisted sample introduction system G Grindlay, S Maestre, L Gras, J Mora Journal of Analytical Atomic Spectrometry 21 (12), 1403-1411, 2006 | 39 | 2006 |
Evaluation of calcium-, carbon-and sulfur-based non-spectral interferences in high-power MIP-OES: comparison with ICP-OES R Serrano, G Grindlay, L Gras, J Mora Journal of Analytical Atomic Spectrometry 34 (8), 1611-1617, 2019 | 32 | 2019 |
Coupling dispersive liquid-liquid microextraction to inductively coupled plasma atomic emission spectrometry: An oxymoron? D Martínez, D Torregrosa, G Grindlay, L Gras, J Mora Talanta 176, 374-381, 2018 | 24 | 2018 |
Lanthanide polymer labels for multiplexed determination of biomarkers in human serum samples by means of size exclusion chromatography-inductively coupled plasma mass spectrometry E Pérez, K Bierla, G Grindlay, J Szpunar, J Mora, R Lobinski Analytica chimica acta 1018, 7-15, 2018 | 22 | 2018 |
Non-spectral interferences due to the presence of sulfuric acid in inductively coupled plasma mass spectrometry MC García-Poyo, G Grindlay, L Gras, MTC de Loos-Vollebregt, J Mora Spectrochimica Acta Part B: Atomic Spectroscopy 105, 71-76, 2015 | 20 | 2015 |
The role of Cymodocea nodosa on the dynamics of trace elements in different marine environmental compartments at the Mar Menor Lagoon (Spain) R Serrano, L Gras, F Giménez-Casalduero, Y del-Pilar-Ruso, G Grindlay, ... Marine pollution bulletin 141, 52-60, 2019 | 19 | 2019 |
A microwave assisted desolvation system based on the use of a TM 010 cavity for inductively coupled plasma based analytical techniques G Grindlay, S Maestre, J Mora, V Hernandis, L Gras Journal of Analytical Atomic Spectrometry 20 (5), 455-461, 2005 | 19 | 2005 |
Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma–mass spectrometry in wine analysis G Grindlay, J Mora, MTC de Loos-Vollebregt, F Vanhaecke Talanta 128, 379-385, 2014 | 18 | 2014 |
Determination of aflatoxin M1 in milk samples by means of an inductively coupled plasma mass spectrometry-based immunoassay E Pérez, P Martínez-Peinado, F Marco, L Gras, JM Sempere, J Mora, ... Food chemistry 230, 721-727, 2017 | 16 | 2017 |
Insight into the origin of carbon matrix effects on the emission signal of atomic lines in inductively coupled plasma optical emission spectrometry R Serrano, G Grindlay, L Gras, J Mora Spectrochimica Acta Part B: Atomic Spectroscopy 177, 106070, 2021 | 15 | 2021 |
Development of preconcentration strategies for the simultaneous ultratrace determination of As, Cd and Pb in foods by ICP-OES: knotted-reactor vs. dispersive liquid–liquid … D Martínez-Rubio, G Grindlay, M Llaver, RG Wuilloud, J Mora Journal of Analytical Atomic Spectrometry 35 (5), 933-942, 2020 | 15 | 2020 |
Evaluation of different competitive immunoassays for aflatoxin M1 determination in milk samples by means of inductively coupled plasma mass spectrometry E Pérez, FM Marco, P Martínez-Peinado, J Mora, G Grindlay Analytica Chimica Acta 1049, 10-19, 2019 | 15 | 2019 |
Determination of metallic nanoparticles in air filters by means single particle inductively coupled plasma mass spectrometry D Torregrosa, G Grindlay, M de la Guardia, L Gras, J Mora Talanta 252, 123818, 2023 | 14 | 2023 |