Carbon nanohorns as a scaffold for the construction of disposable electrochemical immunosensing platforms. Application to the determination of fibrinogen in human plasma and urine
I Ojeda, B Garcinuño, M Moreno-Guzmán, A González-Cortés, ...
Analytical chemistry 86 (15), 7749-7756, 2014
562014
Design of a permeator against vacuum for tritium extraction from eutectic lithium-lead in a DCLL DEMO
B Garcinuno, D Rapisarda, I Fernández, C Moreno, I Palermo, Á Ibarra
Fusion Engineering and Design 117, 226-231, 2017
462017
Design and fabrication of a Permeator Against Vacuum prototype for small scale testing at Lead-Lithium facility
B Garcinuño, D Rapisarda, I Fernández-Berceruelo, D Jiménez-Rey, ...
Fusion Engineering and Design 124, 871-875, 2017
362017
The tritium extraction and removal system for the DCLL-DEMO fusion reactor
B Garcinuño, D Rapisarda, R Antunes, M Utili, I Fernández-Berceruelo, ...
Nuclear Fusion 58 (9), 095002, 2018
332018
The CIEMAT LiPb loop permeation experiment
B Garcinuño, D Rapisarda, I Fernández-Berceruelo, E Carella, J Sanz
Fusion Engineering and Design 146, 1228-1232, 2019
262019
The European Dual Coolant Lithium Lead breeding blanket for DEMO: status and perspectives
D Rapisarda, I Fernández-Berceruelo, A García, JM García, B Garcinuño, ...
Nuclear Fusion 61 (11), 115001, 2021
242021
Integration issues on tritium management of the European DEMO Breeding Blanket and ancillary systems
GA Spagnuolo, R Arredondo, LV Boccaccini, M Coleman, I Cristescu, ...
Fusion Engineering and Design 171, 112573, 2021
212021
Experimental refutation of the deuterium permeability in vanadium, niobium and tantalum
M Malo, B Garcinuño, D Rapisarda
Fusion Engineering and Design 146, 224-227, 2019
212019
Remarks on the performance of the EU DCLL breeding blanket adapted to DEMO 2017
I Fernández-Berceruelo, I Palermo, FR Urgorri, D Rapisarda, B Garcinuño, ...
Fusion Engineering and Design 155, 111559, 2020
192020
Amperometric immunosensor for the determination of ceruloplasmin in human serum and urine based on covalent binding to carbon nanotubes-modified screen-printed electrodes
B Garcinuño, I Ojeda, M Moreno-Guzmán, A González-Cortés, ...
Talanta 118, 61-67, 2014
192014
Design of a system for hydrogen isotopes injection into Lead-Lithium
B Garcinuño, D Rapisarda, C Moreno, J Sanz, Á Ibarra
Fusion Engineering and Design 137, 427-434, 2018
132018
Establishing technical specifications for PbLi eutectic alloy analysis and its relevance in fusion applications
B Garcinuño, R Fernández-Saavedra, T Hernández, MB Gomez, ...
Nuclear Materials and Energy 30, 101146, 2022
122022
Experimental determination of hydrogen isotope transport parameters in vanadium
M Malo, I Peñalva, J Azkurreta, B Garcinuño, HD Liu, D Rapisarda, ...
Membranes 12 (6), 579, 2022
62022
Development of an on-line sensor for hydrogen isotopes monitoring in flowing lithium at DONES
B Garcinuño, D Rapisarda, FR Urgorri, J Herranz, M Malo, J Mollá, ...
Fusion Engineering and Design 161, 112010, 2020
52020
Polarographic determination of the stability constant of the ternary complex formed between cocaine and cobalt thiocyanate
D Vázquez, B Garcinuño, J Tejedor, R Pardo, L Deban
Toxicological & Environmental Chemistry 99 (1), 10-16, 2017
42017
Design and integration of the WCLL Tritium Extraction and Removal System into the European DEMO tokamak Reactor
M Utili, C Alberghi, R Bonifetto, L Candido, A Collaku, B Garcinuño, ...
Energies 16 (13), 5231, 2023
32023
Overview of IFMIF-DONES diagnostics: Requirements and techniques
C Torregrosa-Martin, A Ibarra, J Aguilar, F Ambi, F Arranz, F Arbeiter, ...
Fusion engineering and design 191, 113556, 2023
32023
Integration issues on tritium management of the European DEMO Breeding Blanket and ancillary systems
GA Spagnuolo, R Arredondo Parra, M Coleman, I Cristescu, G Federici, ...
31st Symposium on Fusion Technology (SOFT 2020), 2020
22020
Desing of an experimental facility for Tritium extraction from eutectic Lead-Lithium
BG Pindado
UNED. Universidad Nacional de Educación a Distancia, 2019
22019
Biotin‐Labeled Electropolymerized Network of Gold Nanoparticles for Amperometric Immunodetection of Human Fibrinogen
P Díez, M Gamella, P Martínez‐Ruíz, V Lanzone, A Sánchez, E Sánchez, ...
ChemElectroChem 1 (1), 200-206, 2014
22014