Follow
Selene Pirola
Title
Cited by
Cited by
Year
On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics
S Pirola, Z Cheng, OA Jarral, DP O'Regan, JR Pepper, T Athanasiou, ...
Journal of biomechanics 60, 15-21, 2017
1582017
4D flow analysis of BAV-related fluid-dynamic alterations: evidences of wall shear stress alterations in absence of clinically-relevant aortic anatomical remodeling
F Piatti, F Sturla, MM Bissell, S Pirola, M Lombardi, I Nesteruk, ...
Frontiers in physiology 8, 271023, 2017
712017
4-D flow MRI-based computational analysis of blood flow in patient-specific aortic dissection
S Pirola, B Guo, C Menichini, S Saitta, W Fu, Z Dong, XY Xu
IEEE Transactions on Biomedical Engineering 66 (12), 3411-3419, 2019
662019
The influence of inlet velocity profile on predicted flow in type B aortic dissection
CH Armour, B Guo, S Pirola, S Saitta, Y Liu, Z Dong, XY Xu
Biomechanics and modeling in mechanobiology 20, 481-490, 2021
562021
Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
S Pirola, OA Jarral, DP O'Regan, G Asimakopoulos, JR Anderson, ...
APL bioengineering 2 (2), 2018
532018
Towards the improved quantification of in vivo abnormal wall shear stresses in BAV-affected patients from 4D-flow imaging: Benchmarking and application to real data
F Piatti, S Pirola, M Bissell, I Nesteruk, F Sturla, A Della Corte, A Redaelli, ...
Journal of biomechanics 50, 93-101, 2017
502017
Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations
S Saitta, S Pirola, F Piatti, E Votta, F Lucherini, F Pluchinotta, M Carminati, ...
Journal of biomechanics 94, 13-21, 2019
462019
High wall shear stress can predict wall degradation in ascending aortic aneurysms: an integrated biomechanics study
MY Salmasi, S Pirola, S Sasidharan, SM Fisichella, A Redaelli, OA Jarral, ...
Frontiers in bioengineering and biotechnology 9, 750656, 2021
432021
Analysis of turbulence effects in a patient-specific aorta with aortic valve stenosis
EL Manchester, S Pirola, MY Salmasi, DP O’Regan, T Athanasiou, XY Xu
Cardiovascular engineering and technology 12, 438-453, 2021
332021
High wall stress may predict the formation of stent-graft–induced new entries after thoracic endovascular aortic repair
C Menichini, S Pirola, B Guo, W Fu, Z Dong, XY Xu
Journal of Endovascular Therapy 25 (5), 571-577, 2018
302018
Evaluation and verification of patient-specific modelling of type B aortic dissection
CH Armour, B Guo, S Saitta, S Pirola, Y Liu, Z Dong, XY Xu
Computers in biology and medicine 140, 105053, 2022
232022
Phase-contrast magnetic resonance imaging and computational fluid dynamics assessment of thoracic aorta blood flow: a literature review
OA Jarral, MKH Tan, MY Salmasi, S Pirola, JR Pepper, DP O’Regan, ...
European Journal of Cardio-Thoracic Surgery 57 (3), 438-446, 2020
182020
Evaluation of computational methodologies for accurate prediction of wall shear stress and turbulence parameters in a patient-specific aorta
EL Manchester, S Pirola, MY Salmasi, DP O’Regan, T Athanasiou, XY Xu
Frontiers in Bioengineering and Biotechnology 10, 836611, 2022
162022
Dissection level within aortic wall layers is associated with propagation of type B aortic dissection: a swine model study
B Guo, Z Dong, S Pirola, Y Liu, C Menichini, XY Xu, D Guo, W Fu
European Journal of Vascular and Endovascular Surgery 58 (3), 415-425, 2019
122019
Qualitative and quantitative assessments of blood flow on tears in type B aortic dissection with different morphologies
S Saitta, B Guo, S Pirola, C Menichini, D Guo, Y Shan, Z Dong, XY Xu, ...
Frontiers in Bioengineering and Biotechnology 9, 742985, 2021
112021
Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection
B Guo, S Pirola, D Guo, Z Dong, XY Xu, W Fu
Journal of Vascular Surgery Cases, Innovations and Techniques 4 (1), 67-71, 2018
102018
Geometry and flow in ascending aortic aneurysms are influenced by left ventricular outflow tract orientation: Detecting increased wall shear stress on the outer curve of …
MY Salmasi, S Pirola, S Mahuttanatan, SM Fisichella, S Sengupta, ...
The Journal of Thoracic and Cardiovascular Surgery 166 (1), 11-21. e1, 2023
72023
Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta
S Saitta, L Maga, C Armour, E Votta, DP O’Regan, MY Salmasi, ...
Computer Methods and Programs in Biomedicine 233, 107468, 2023
72023
Fluid-structure interaction within models of patient-specific arteries: computational simulations and experimental validations
S Schoenborn, S Pirola, MA Woodruff, MC Allenby
IEEE Reviews in Biomedical Engineering, 2022
72022
Effect of vessel tortuosity on stress concentration at the distal stent–vessel interface: Possible link with new entry formation through biomechanical simulation
WT Tan, YM Liew, MJ Mohamed Mokhtarudin, S Pirola, WN Wan Ab Naim, ...
Journal of Biomechanical Engineering 143 (8), 081005, 2021
72021
The system can't perform the operation now. Try again later.
Articles 1–20