Follow
Natalia Saltybaeva
Natalia Saltybaeva
Dr.
Verified email at usz.ch
Title
Cited by
Cited by
Year
Estimates of effective dose for CT scans of the lower extremities
N Saltybaeva, ME Jafari, M Hupfer, WA Kalender
Radiology 273 (1), 153-159, 2014
1552014
Precise and automatic patient positioning in computed tomography: avatar modeling of the patient surface using a 3-dimensional camera
N Saltybaeva, B Schmidt, A Wimmer, T Flohr, H Alkadhi
Investigative Radiology 53 (11), 641-646, 2018
792018
Dedicated breast computed tomography with a photon-counting detector: initial results of clinical in vivo imaging
N Berger, M Marcon, N Saltybaeva, WA Kalender, H Alkadhi, ...
Investigative radiology 54 (7), 409-418, 2019
662019
Assessment of patient dose from CT localizer radiographs
B Schmidt, N Saltybaeva, D Kolditz, WA Kalender
Medical physics 40 (8), 084301, 2013
482013
Organ dose and attributable cancer risk in lung cancer screening with low-dose computed tomography
N Saltybaeva, K Martini, T Frauenfelder, H Alkadhi
PloS one 11 (5), e0155722, 2016
442016
Vertical off‐centering affects organ dose in chest CT: evidence from Monte Carlo simulations in anthropomorphic phantoms
N Saltybaeva, H Alkadhi
Medical physics 44 (11), 5697-5704, 2017
422017
Bone mineral density quantification from localizer radiographs: accuracy and precision of energy-integrating detector CT and photon-counting detector CT
T Nowak, M Eberhard, B Schmidt, D Frey, O Distler, N Saltybaeva, ...
Radiology 298 (1), 147-152, 2021
262021
Lesion detectability and radiation dose in spiral breast CT with photon-counting detector technology: a phantom study
S Shim, N Saltybaeva, N Berger, M Marcon, H Alkadhi, A Boss
Investigative radiology 55 (8), 515-523, 2020
262020
Effect of localizer radiography projection on organ dose at chest CT with automatic tube current modulation
N Saltybaeva, A Krauss, H Alkadhi
Radiology 282 (3), 842-849, 2017
242017
Spiral breast computed tomography (CT): Signal-to-noise and dose optimization using 3D-printed phantoms
M Germann, S Shim, F Angst, N Saltybaeva, A Boss
European radiology 31, 3693-3702, 2021
192021
Dose optimization for computed tomography localizer radiographs for low-dose lung computed tomography examinations
BT Schmidt, M Hupfer, N Saltybaeva, D Kolditz, WA Kalender
Investigative Radiology 52 (2), 81-86, 2017
182017
Generating and using patient-specific whole-body models for organ dose estimates in CT with increased accuracy: feasibility and validation
WA Kalender, N Saltybaeva, D Kolditz, M Hupfer, M Beister, B Schmidt
Physica Medica 30 (8), 925-933, 2014
182014
How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT
A Euler, N Saltybaeva, H Alkadhi
European Radiology 29, 6790-6793, 2019
172019
Robustness of radiomic features in magnetic resonance imaging for patients with glioblastoma: Multi-center study
N Saltybaeva, S Tanadini-Lang, D Vuong, S Burgermeister, M Mayinger, ...
Physics and imaging in radiation oncology 22, 131-136, 2022
162022
Systematic literature review on the benefit of patient protection shielding during medical X-ray imaging: towards a discontinuation of the current practice
ET Samara, N Saltybaeva, MS Merce, S Gianolini, M Ith
Physica Medica 94, 102-109, 2022
162022
Radiomic analysis to predict outcome in recurrent glioblastoma based on multi-center MR imaging from the prospective DIRECTOR trial
A Vils, M Bogowicz, S Tanadini-Lang, D Vuong, N Saltybaeva, J Kraft, ...
Frontiers in oncology 11, 636672, 2021
162021
Radiation dose reduction from computed tomography localizer radiographs using a tin spectral shaping filter
N Saltybaeva, A Krauss, H Alkadhi
Medical physics 46 (2), 544-549, 2019
162019
Prospective randomized comparison of high-pitch CT at 80 kVp under free breathing with standard-pitch CT at 100 kVp under breath-hold for detection of pulmonary embolism
K Martini, A Meier, K Higashigaito, N Saltybaeva, H Alkadhi, ...
Academic radiology 23 (11), 1335-1341, 2016
162016
Radiation dose to the fetus from computed tomography of pregnant patients—development and validation of a web-based tool
N Saltybaeva, A Platon, PA Poletti, R Hinzpeter, MS Merce, H Alkadhi
Investigative Radiology 55 (12), 762-768, 2020
122020
Vertical off-centering in reduced dose chest-CT: impact on effective dose and image noise values
M Eberhard, C Blüthgen, BK Barth, T Frauenfelder, N Saltybaeva, ...
Academic radiology 27 (4), 508-517, 2020
112020
The system can't perform the operation now. Try again later.
Articles 1–20