Follow
Jason W. Sidabras
Title
Cited by
Cited by
Year
Saturation recovery EPR and ELDOR at W-band for spin labels
W Froncisz, TG Camenisch, JJ Ratke, JR Anderson, WK Subczynski, ...
Journal of Magnetic Resonance 193 (2), 297-304, 2008
532008
Dielectric microwave resonators in TE011 cavities for electron paramagnetic resonance spectroscopy
RR Mett, JW Sidabras, IS Golovina, JS Hyde
Review of scientific instruments 79 (9), 2008
522008
Electron paramagnetic resonance dosimetry for a large-scale radiation incident
HM Swartz, AB Flood, BB Williams, R Dong, SG Swarts, X He, O Grinberg, ...
Health physics 103 (3), 255-267, 2012
492012
Multipurpose EPR loop-gap resonator and cylindrical TE011 cavity for aqueous samples at 94GHz
JW Sidabras, RR Mett, W Froncisz, TG Camenisch, JR Anderson, ...
Review of scientific instruments 78 (3), 2007
472007
Detection of undistorted continuous wave (CW) electron paramagnetic resonance (EPR) spectra with non-adiabatic rapid sweep (NARS) of the magnetic field
AW Kittell, TG Camenisch, JJ Ratke, JW Sidabras, JS Hyde
Journal of Magnetic Resonance 211 (2), 228-233, 2011
362011
Aqueous flat-cells perpendicular to the electric field for use in electron paramagnetic resonance spectroscopy, II: design
JW Sidabras, RR Mett, JS Hyde
Journal of Magnetic Resonance 172 (2), 333-341, 2005
312005
Development and validation of an ex vivo electron paramagnetic resonance fingernail biodosimetric method
X He, SG Swarts, E Demidenko, AB Flood, O Grinberg, J Gui, M Mariani, ...
Radiation Protection Dosimetry 159 (1-4), 172-181, 2014
292014
Advances towards using finger/toenail dosimetry to triage a large population after potential exposure to ionizing radiation
X He, J Gui, TP Matthews, BB Williams, SG Swarts, O Grinberg, ...
Radiation measurements 46 (9), 882-887, 2011
292011
Uniform radio frequency fields in loop-gap resonators for EPR spectroscopy
RR Mett, JW Sidabras, JS Hyde
Applied Magnetic Resonance 31 (3), 573-589, 2007
272007
Restoring susceptibility induced MRI signal loss in rat brain at 9.4 T: a step towards whole brain functional connectivity imaging
R Li, X Liu, JW Sidabras, ES Paulson, A Jesmanowicz, AS Nencka, ...
PLoS One 10 (4), e0119450, 2015
262015
Microwave frequency modulation in CW EPR at W-band using a loop-gap resonator
JS Hyde, W Froncisz, JW Sidabras, TG Camenisch, JR Anderson, ...
Journal of Magnetic Resonance 185 (2), 259-263, 2007
262007
Extending electron paramagnetic resonance to nanoliter volume protein single crystals using a self-resonant microhelix
JW Sidabras, J Duan, M Winkler, T Happe, R Hussein, A Zouni, D Suter, ...
Science Advances 5 (10), eaay1394, 2019
242019
Surface loop resonator design for in vivo EPR tooth dosimetry using finite element analysis
JD Pollock, BB Williams, JW Sidabras, O Grinberg, I Salikhov, ...
Health Physics 98 (2), 339-344, 2010
242010
Coupling of waveguide and resonator by inductive and capacitive irises for EPR spectroscopy
RR Mett, JW Sidabras, JS Hyde
Applied magnetic resonance 35 (2), 285-318, 2009
242009
Developments in biodosimetry methods for triage with a focus on X-band electron paramagnetic resonance in vivo fingernail dosimetry
SG Swarts, JW Sidabras, O Grinberg, DS Tipikin, MM Kmiec, ...
Health physics 115 (1), 140-150, 2018
212018
Moving difference (MDIFF) non-adiabatic rapid sweep (NARS) EPR of copper (II)
JS Hyde, B Bennett, AW Kittell, JM Kowalski, JW Sidabras
Journal of Magnetic Resonance 236, 15-25, 2013
202013
EPR of Cu2+ prion protein constructs at 2 GHz using the g⊥ region to characterize nitrogen ligation
JS Hyde, B Bennett, ED Walter, GL Millhauser, JW Sidabras, ...
Biophysical journal 96 (8), 3354-3362, 2009
192009
Photobleaching of pheomelanin increases its phototoxic potential: Physicochemical studies of synthetic pheomelanin subjected to aerobic photolysis
A Zadlo, G Szewczyk, M Sarna, TG Camenisch, JW Sidabras, S Ito, ...
Pigment cell & melanoma research 32 (3), 359-372, 2019
182019
Possible nature of the radiation-induced signal in nails: high-field EPR, confirming chemical synthesis, and quantum chemical calculations
DS Tipikin, SG Swarts, JW Sidabras, F Trompier, HM Swartz
Radiation Protection Dosimetry 172 (1-3), 112-120, 2016
172016
Spin-label W-band EPR with seven-loop–six-gap resonator: application to lens membranes derived from eyes of a single donor
L Mainali, JW Sidabras, TG Camenisch, JJ Ratke, M Raguz, JS Hyde, ...
Applied magnetic resonance 45, 1343-1358, 2014
162014
The system can't perform the operation now. Try again later.
Articles 1–20