Gyroid porous titanium structures: a versatile solution to be used as scaffolds in bone defect reconstruction A Yánez, A Cuadrado, O Martel, H Afonso, D Monopoli Materials & Design 140, 21-29, 2018 | 193 | 2018 |
Compressive behaviour of gyroid lattice structures for human cancellous bone implant applications A Yánez, A Herrera, O Martel, D Monopoli, H Afonso Materials Science and Engineering: C 68, 445-448, 2016 | 139 | 2016 |
Influence of load orientation and of types of loads on the mechanical properties of porous Ti6Al4V biomaterials A Cuadrado, A Yánez, O Martel, S Deviaene, D Monopoli Materials & Design 135, 309-318, 2017 | 85 | 2017 |
Computational study and experimental validation of porous structures fabricated by electron beam melting: A challenge to avoid stress shielding A Herrera, A Yánez, O Martel, H Afonso, D Monopoli Materials Science and Engineering: C 45, 89-93, 2014 | 51 | 2014 |
Surface roughness effects on the fatigue behaviour of gyroid cellular structures obtained by additive manufacturing A Yánez, MP Fiorucci, A Cuadrado, O Martel, D Monopoli International Journal of Fatigue 138, 105702, 2020 | 49 | 2020 |
Fatigue behaviour and equivalent diameter of single Ti-6Al-4V struts fabricated by Electron Bean Melting orientated to porous lattice structures A Pérez-Sánchez, A Yánez, A Cuadrado, O Martel, N Nuńo Materials & Design 155, 106-115, 2018 | 37 | 2018 |
Bionic design and verification of 3D printed PEEK costal cartilage prosthesis C Zhang, L Wang, J Kang, OM Fuentes, D Li Journal of the Mechanical Behavior of Biomedical Materials 103, 103561, 2020 | 31 | 2020 |
A new device for the fixation of anterior cruciate ligament tendon grafts: design and experimental study O Martel, JA Carta, G Garcés Medical engineering & physics 29 (1), 163-168, 2007 | 13 | 2007 |
Análisis comparativo de prótesis de cadera: Implantes tradicionales frente a implantes mínimamente invasivos O Martel, H Alfonso, J Bermejo, A Cuadrado, D Monopoli Universidad Nacional de Educación a Distancia (Espańa), 2011 | 12 | 2011 |
The Influence of Dimensions and Powder Recycling on the Roughness and Mechanical Properties of Ti-6Al-4V Parts Fabricated by Laser Powder Bed Fusion A Yánez, MP Fiorucci, O Martel, A Cuadrado Materials 15 (16), 5787, 2022 | 9 | 2022 |
Biomechanical characterization of custom-made dynamic implants fabricated by Electron Beam Melting for anterior chest wall reconstruction MP Fiorucci, A Cuadrado, A Yanez, O Martel, B Mentado, D Monopoli Materials & Design 206, 109758, 2021 | 7 | 2021 |
Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study GL Garcés, O Martel, A Yánez, A Cuadrado BMC Musculoskeletal Disorders 20, 1-8, 2019 | 7 | 2019 |
In Vitro Testing of 2 Adjustable-Loop Cortical Suspensory Fixation Systems Versus Interference Screw for Anterior Cruciate Ligament Reconstruction GL Garcés, O Martel, A Yánez, I Manchado-Herrera, LM Motta Orthopaedic Journal of Sports Medicine 9 (9), 23259671211031652, 2021 | 5 | 2021 |
Does the modelling of the pectus bar affect its stability? Rationale for using a short flat bar D Pérez, O Martel, A Yánez, JR Cano, A Cuadrado, G Torrent, L López Interactive CardioVascular and Thoracic Surgery 30 (1), 11-17, 2020 | 5 | 2020 |
Can an expansion device be used in anterior cruciate ligament reconstruction? An in vitro study of soft tissue graft tibial fixation O Martel, GL Garcés, A Yánez, A Cuadrado, JF Cárdenes The Knee 23 (6), 1049-1054, 2016 | 5 | 2016 |
Influencia de la velocidad en los ensayos de los sistemas de fijación de injertos de ligamento cruzado anterior O Martel, JF Cárdenes, JA Carta, G Garcés, JM Quintana 88 Congreso Iberoamericano de Ingenierıa mecánica. http://con greso. pucp …, 2011 | 5 | 2011 |
Influence of the number and position of stripped screws on plate–screw construct biomechanical properties GL Garcés, A Yánez, A Cuadrado, O Martel Injury 48, S54-S59, 2017 | 4 | 2017 |
Experimental analysis of the minimally invasive plate osteosynthesis technique applied with non-locking screws and screw locking elements A Yanez, A Cuadrado, PJ Cabrera, O Martel, G Garces Medical engineering & physics 36 (11), 1543-1548, 2014 | 3 | 2014 |
Influence of the crosshead rate on the mechanical properties of fixation systems of ACL tendon grafts O Martel, JF Cárdenes, G Garcés, JA Carta Journal of applied biomechanics 25 (4), 313-321, 2009 | 3 | 2009 |
Validación y rediseńo de mecanismo de expansión radial para la fijación ósea de injerto de ligamento cruzado anterior de la rodilla ÓM Fuentes Universidad de Las Palmas de Gran Canaria, 2003 | 2 | 2003 |