Novel three-Dimensional molecularly imprinted polymer-coated carbon nanotubes (3D-CNTs@ MIP) for selective detection of profenofos in food M Amatatongchai, W Sroysee, P Sodkrathok, N Kesangam, S Chairam, ... Analytica chimica acta 1076, 64-72, 2019 | 101 | 2019 |
Highly sensitive and selective electrochemical paper-based device using a graphite screen-printed electrode modified with molecularly imprinted polymers coated Fe3O4@ Au@ SiO2 … M Amatatongchai, J Sitanurak, W Sroysee, S Sodanat, S Chairam, ... Analytica chimica acta 1077, 255-265, 2019 | 96 | 2019 |
Thin-film organic photodiodes for integrated on-chip chemiluminescence detection–application to antioxidant capacity screening X Wang, M Amatatongchai, D Nacapricha, O Hofmann, JC de Mello, ... Sensors and Actuators B: Chemical 140 (2), 643-648, 2009 | 87 | 2009 |
Selective colorimetric sensors based on the monitoring of an unmodified silver nanoparticles (AgNPs) reduction for a simple and rapid determination of mercury P Jarujamrus, M Amatatongchai, A Thima, T Khongrangdee, ... Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 142, 86-93, 2015 | 85 | 2015 |
Simple flow injection for screening of total antioxidant capacity by amperometric detection of DPPH radical on carbon nanotube modified-glassy carbon electrode M Amatatongchai, S Laosing, O Chailapakul, D Nacapricha Talanta 97, 267-272, 2012 | 75 | 2012 |
Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes–PDDA–gold nanoparticles M Amatatongchai, W Sroysee, S Chairam, D Nacapricha Talanta 133, 134-141, 2015 | 67 | 2015 |
Chromatic analysis by monitoring unmodified silver nanoparticles reduction on double layer microfluidic paper-based analytical devices for selective and sensitive determination … R Meelapsom, P Jarujamrus, M Amatatongchai, S Chairam, C Kulsing, ... Talanta 155, 193-201, 2016 | 62 | 2016 |
Mimicking peroxidase-like activity of nitrogen-doped carbon dots (N-CDs) coupled with a laminated three-dimensional microfluidic paper-based analytical device (laminated 3D … N Kitchawengkul, A Prakobkij, W Anutrasakda, N Yodsin, ... Analytical Chemistry 93 (18), 6989-6999, 2021 | 59 | 2021 |
Selective amperometric flow-injection analysis of carbofuran using a molecularly-imprinted polymer and gold-coated-magnetite modified carbon nanotube-paste electrode M Amatatongchai, W Sroysee, P Jarujamrus, D Nacapricha, PA Lieberzeit Talanta 179, 700-709, 2018 | 58 | 2018 |
Use of a smartphone as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury in water samples P Jarujamrus, R Meelapsom, S Pencharee, A Obma, M Amatatongchai, ... Analytical Sciences 34 (1), 75-81, 2018 | 55 | 2018 |
A microfluidic system for evaluation of antioxidant capacity based on a peroxyoxalate chemiluminescence assay M Amatatongchai, O Hofmann, D Nacapricha, O Chailapakul, AJ DeMello Analytical and bioanalytical chemistry 387, 277-285, 2007 | 51 | 2007 |
Enhanced selectivity and sensitivity for colorimetric determination of glyphosate using Mn–ZnS quantum dot embedded molecularly imprinted polymers combined with a 3D … P Sawetwong, S Chairam, P Jarujamrus, M Amatatongchai Talanta 225, 122077, 2021 | 46 | 2021 |
Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode M Amatatongchai, W Sroysee, S Chairam, D Nacapricha Talanta 166, 420-427, 2017 | 46 | 2017 |
Determination of iodide by detection of iodine using gas-diffusion flow injection and chemiluminescence N Ratanawimarnwong, N Amornthammarong, N Choengchan, ... Talanta 65 (3), 756-761, 2005 | 44 | 2005 |
A sensitive and selective on-line amperometric sulfite biosensor using sulfite oxidase immobilized on a magnetite-gold-folate nanocomposite modified carbon-paste electrode W Sroysee, K Ponlakhet, S Chairam, P Jarujamrus, M Amatatongchai Talanta 156, 154-162, 2016 | 41 | 2016 |
Flow-injection determination of iodide ion in nuclear emergency tablets, using boron-doped diamond thin film electrode O Chailapakul, M Amatatongchai, P Wilairat, K Grudpan, D Nacapricha Talanta 64 (5), 1253-1258, 2004 | 41 | 2004 |
Fabricating simple wax screen-printing paper-based analytical devices to demonstrate the concept of limiting reagent in acid–base reactions P Namwong, P Jarujamrus, M Amatatongchai, S Chairam Journal of Chemical Education 95 (2), 305-309, 2018 | 40 | 2018 |
Molecularly imprinted polymers to detect profenofos and carbofuran selectively with QCM sensors W Sroysee, S Chunta, M Amatatongchai, PA Lieberzeit Physics in Medicine 7, 100016, 2019 | 38 | 2019 |
Electrocatalytic Oxidation of Ascorbic Acid Using a Poly(aniline-co-m-ferrocenylaniline) Modified Glassy Carbon Electrode S Chairam, W Sriraksa, M Amatatongchai, E Somsook Sensors 11 (11), 10166-10179, 2011 | 38 | 2011 |
Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide nanoparticle-modified carbon-paste-electrode N Nontawong, M Amatatongchai, S Thimoonnee, S Laosing, ... Journal of Pharmaceutical and Biomedical Analysis 175, 112770, 2019 | 36 | 2019 |