Follow
Ramón Cabello López
Title
Cited by
Cited by
Year
Energy improvements of CO2 transcritical refrigeration cycles using dedicated mechanical subcooling
R Llopis, R Cabello, D Sánchez, E Torrella
International Journal of Refrigeration 55, 129-141, 2015
1832015
Experimental evaluation of a CO2 transcritical refrigeration plant with dedicated mechanical subcooling
R Llopis, L Nebot-Andrés, R Cabello, D Sánchez, J Catalán-Gil
International Journal of Refrigeration 69, 361-368, 2016
1472016
Energy and environmental comparison of two-stage solutions for commercial refrigeration at low temperature: Fluids and systems
R Llopis, D Sánchez, C Sanz-Kock, R Cabello, E Torrella
Applied Energy 138, 133-142, 2015
1292015
Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor
E Torrella, R Llopis, R Cabello
International journal of refrigeration 32 (2), 307-315, 2009
732009
Experimental evaluation of an internal heat exchanger in a CO2 subcritical refrigeration cycle with gas-cooler
R Llopis, C Sanz-Kock, R Cabello, D Sánchez, E Torrella
Applied Thermal Engineering 80, 31-41, 2015
602015
Effects caused by the internal heat exchanger at the low temperature cycle in a cascade refrigeration plant
R Llopis, C Sanz-Kock, R Cabello, D Sánchez, L Nebot-Andrés, ...
Applied Thermal Engineering 103, 1077-1086, 2016
572016
Experimental determination of the optimum working conditions of a transcritical CO2 refrigeration plant with integrated mechanical subcooling
L Nebot-Andrés, J Catalán-Gil, D Sánchez, D Calleja-Anta, R Cabello, ...
International Journal of Refrigeration 113, 266-275, 2020
552020
Energy analysis of dedicated and integrated mechanical subcooled CO2 boosters for supermarket applications
J Catalán-Gil, R Llopis, D Sánchez, L Nebot-Andres, R Cabello
International Journal of Refrigeration 101, 11-23, 2019
502019
Experimental analysis of R-450A and R-513A as replacements of R-134a and R-507A in a medium temperature commercial refrigeration system
R Llopis, D Sánchez, R Cabello, J Catalán-Gil, L Nebot-Andrés
International journal of refrigeration 84, 52-66, 2017
422017
Conversion of a direct to an indirect commercial (HFC134a/CO2) cascade refrigeration system: Energy impact analysis
D Sánchez, R Llopis, R Cabello, J Catalán-Gil, L Nebot-Andrés
International Journal of Refrigeration 73, 183-199, 2017
422017
R-454C, R-459B, R-457A and R-455A as low-GWP replacements of R-404A: Experimental evaluation and optimization
R Llopis, D Calleja-Anta, D Sánchez, L Nebot-Andrés, J Catalán-Gil, ...
International Journal of Refrigeration 106, 133-143, 2019
392019
Experimental evaluation of HCFC-22 replacement by the drop-in fluids HFC-422A and HFC-417B for low temperature refrigeration applications
R Llopis, R Cabello, D Sánchez, E Torrella, J Patiño, JG Sánchez
Applied Thermal Engineering 31 (6-7), 1323-1331, 2011
372011
A dynamic model of a shell-and-tube condenser operating in a vapour compression refrigeration plant
R Llopis, R Cabello, E Torrella
International journal of thermal sciences 47 (7), 926-934, 2008
352008
Experimental determination of the optimum working conditions of a commercial transcritical CO2 refrigeration plant with a R-152a dedicated mechanical subcooling.
L Nebot-Andrés, D Sánchez, D Calleja-Anta, R Cabello, R Llopis
International Journal of Refrigeration 121, 258-268, 2021
262021
R-407H as drop-in of R-404A. Experimental analysis in a low temperature direct expansion commercial refrigeration system
R Llopis, D Sánchez, R Cabello, L Nebot-Andres, J Catalán-Gil
International Journal of Refrigeration 80, 11-23, 2017
212017
Experimental energetic analysis of the liquid injection effect in a two-stage refrigeration facility using a compound compressor
RL Doménech, ET Alcaraz, RC López, JAL Bernad
Hvac&R Research 13 (5), 819-831, 2007
192007
Experimental evaluation of the energy performance of an air vortex tube when the inlet parameters are varied
E Torrella Alcaraz, J Patiño, D Sánchez, R Llopis, R Cabello
Open Mechanical Engineering Journal 7 (1), 98-107, 2013
112013
Conversion of a direct to an indirect refrigeration system at medium temperature using R-134a and R-507A: An energy impact analysis
R Llopis, D Sánchez, R Cabello, J Catalán-Gil, L Nebot-Andrés
Applied Sciences 8 (2), 247, 2018
92018
Development and implementation of a low-cost data acquisition system based on Arduino for refrigeration facilities
DS García-Vacas, JP Pérez, RC López, RL Doménech, ET Alcaraz
EDULEARN15 Proceedings, 4246-4251, 2015
42015
Las máquinas de producción de frío por adsorción con la mezcla sílica gel-agua
E Torrella Alcaraz, D Sánchez García-Vacas, R Cabello López, ...
Reed Business Information, 2011
42011
The system can't perform the operation now. Try again later.
Articles 1–20