Follow
David Schmidtke
David Schmidtke
Professor of Biomedical Engineering, University of Texas at Dallas
Verified email at utdallas.edu
Title
Cited by
Cited by
Year
Design and optimization of a selective subcutaneously implantable glucose electrode based on" wired" glucose oxidase
E Csoeregi, DW Schmidtke, A Heller
Analytical Chemistry 67 (7), 1240-1244, 1995
7861995
Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin
DW Schmidtke, AC Freeland, A Heller, RT Bonnecaze
Proceedings of the National Academy of Sciences 95 (1), 294-299, 1998
7031998
Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors
CP Quinn, MV Pishko, DW Schmidtke, M Ishikawa, JG Wagner, P Raskin, ...
American Journal of Physiology-Endocrinology and Metabolism 269 (1), E155-E161, 1995
6241995
Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode
E Csoeregi, CP Quinn, DW Schmidtke, SE Lindquist, MV Pishko, L Ye, ...
Analytical Chemistry 66 (19), 3131-3138, 1994
5331994
Direct observation of membrane tethers formed during neutrophil attachment to platelets or P-selectin under physiological flow
DW Schmidtke, SL Diamond
The Journal of cell biology 149 (3), 719-730, 2000
3182000
Amperometric biosensors based on redox polymer− carbon nanotube− enzyme composites
PP Joshi, SA Merchant, Y Wang, DW Schmidtke
Analytical Chemistry 77 (10), 3183-3188, 2005
3152005
Scanning electrochemical microscopy. 24. Enzyme ultramicroelectrodes for the measurement of hydrogen peroxide at surfaces
BR Horrocks, D Schmidtke, A Heller, AJ Bard
Analytical Chemistry 65 (24), 3605-3614, 1993
2841993
Accuracy of the one-point in vivo calibration of “wired” glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose …
DW Schmidtke, A Heller
Analytical Chemistry 70 (10), 2149-2155, 1998
2721998
Selectin-like kinetics and biomechanics promote rapid platelet adhesion in flow: the GPIbα-vWF tether bond
TA Doggett, G Girdhar, A Lawshé, DW Schmidtke, IJ Laurenzi, ...
Biophysical journal 83 (1), 194-205, 2002
2422002
Comparison of PSGL-1 microbead and neutrophil rolling: microvillus elongation stabilizes P-selectin bond clusters
EYH Park, MRJ Smith, ES Stropp, KR Snapp, JA DiVietro, WF Walker, ...
Biophysical journal 82 (4), 1835-1847, 2002
1982002
Initial evaluation of a 290-μm diameter subcutaneous glucose sensor: glucose monitoring with a biocompatible, flexible-wire, enzyme-based amperometric microsensor in diabetic …
M Ishikawa, DW Schmidtke, P Raskin, CAP Quinn
Journal of Diabetes and its Complications 12 (6), 295-301, 1998
1681998
Dynamic alterations of membrane tethers stabilize leukocyte rolling on P-selectin
V Ramachandran, M Williams, T Yago, DW Schmidtke, RP McEver
Proceedings of the National Academy of Sciences 101 (37), 13519-13524, 2004
1612004
Nanostructured biosensors built by layer-by-layer electrostatic assembly of enzyme-coated single-walled carbon nanotubes and redox polymers
Y Wang, PP Joshi, KL Hobbs, MB Johnson, DW Schmidtke
Langmuir 22 (23), 9776-9783, 2006
1492006
Adsorption of glucose oxidase onto single-walled carbon nanotubes and its application in layer-by-layer biosensors
TW Tsai, G Heckert, LF Neves, Y Tan, DY Kao, RG Harrison, DE Resasco, ...
Analytical chemistry 81 (19), 7917-7925, 2009
1452009
Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode
JG Wagner, DW Schmidtke, CP Quinn, TF Fleming, B Bernacky, A Heller
Proceedings of the National Academy of Sciences 95 (11), 6379-6382, 1998
1441998
Defining the Period of Recovery of the Glucose Concentration after its Local Perturbation by the Implantation of a Miniature Sensor
T Chen, DW Schmidtke, A Heller
Walter de Gruyter 40 (8), 786-789, 2002
1402002
Separable requirements for cytoplasmic domain of PSGL-1 in leukocyte rolling and signaling under flow
JJ Miner, L Xia, T Yago, J Kappelmayer, Z Liu, AG Klopocki, B Shao, ...
Blood, The Journal of the American Society of Hematology 112 (5), 2035-2045, 2008
1262008
High-sensitivity amperometric biosensors based on ferrocene-modified linear poly (ethylenimine)
SA Merchant, TO Tran, MT Meredith, TC Cline, DT Glatzhofer, ...
Langmuir 25 (13), 7736-7742, 2009
1102009
High current density ferrocene-modified linear poly (ethylenimine) bioanodes and their use in biofuel cells
MT Meredith, DY Kao, D Hickey, DW Schmidtke, DT Glatzhofer
Journal of the Electrochemical Society 158 (2), B166, 2010
1032010
Enzyme cascade for catalyzing sucrose oxidation in a biofuel cell
DP Hickey, F Giroud, DW Schmidtke, DT Glatzhofer, SD Minteer
Acs Catalysis 3 (12), 2729-2737, 2013
932013
The system can't perform the operation now. Try again later.
Articles 1–20