Photon-counting x-ray detectors for CT M Danielsson, M Persson, M Sjölin Physics in Medicine & Biology 66 (3), 03TR01, 2021 | 175 | 2021 |
Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning J da Silva, F Grönberg, B Cederström, M Persson, M Sjölin, Z Alagic, ... Journal of Medical Imaging 6 (4), 043502-043502, 2019 | 53 | 2019 |
Count rate performance of a silicon-strip detector for photon-counting spectral CT X Liu, F Grönberg, M Sjölin, S Karlsson, M Danielsson Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2016 | 48 | 2016 |
Feasibility of unconstrained three-material decomposition: imaging an excised human heart using a prototype silicon photon-counting CT detector F Grönberg, J Lundberg, M Sjölin, M Persson, R Bujila, H Bornefalk, ... European radiology 30, 5904-5912, 2020 | 25 | 2020 |
Digital count summing vs analog charge summing for photon counting detectors: A performance simulation study SS Hsieh, M Sjolin Medical physics 45 (9), 4085-4093, 2018 | 25 | 2018 |
Improved signal-to-noise ratio for non-perpendicular detection angles in x-ray fluorescence computed tomography (XFCT) M Sjölin, M Danielsson Physics in Medicine & Biology 59 (21), 6507, 2014 | 20 | 2014 |
Count statistics of nonparalyzable photon‐counting detectors with nonzero pulse length F Grönberg, M Danielsson, M Sjölin Medical Physics 45 (8), 3800-3811, 2018 | 13 | 2018 |
Silicon photon-counting detector for full-field CT using an ASIC with adjustable shaping time C Sundberg, M Persson, M Sjölin, JJ Wikner, M Danielsson Journal of Medical Imaging 7 (5), 053503-053503, 2020 | 11 | 2020 |
Managing geometric misalignment in x-ray imaging systems M Sjolin, LIU Xuejin, M Danielsson US Patent 10,610,191, 2020 | 11 | 2020 |
X-ray imaging for enabling assessment of scoliosis M Danielsson, LIU Xuejin, M Sjolin US Patent 10,143,417, 2018 | 6 | 2018 |
X-ray detector system based on photon counting C Svensson, M Persson, M Sjolin, M Danielsson US Patent 10,067,240, 2018 | 4 | 2018 |
Increased count-rate performance and dose efficiency for silicon photon-counting detectors for full-field CT using an ASIC with adjustable shaping time C Sundberg, M Persson, A Ehliar, M Sjölin, J Wikner, M Danielsson Medical Imaging 2019: Physics of Medical Imaging 10948, 486-497, 2019 | 3 | 2019 |
Radiation hard silicon detectors for x-ray imaging M Danielsson, S Karlsson, C Xu, M Sjolin US Patent 10,191,162, 2019 | 3 | 2019 |
Photon counting detector M Danielsson, S Karlsson, LIU Xuejin, M Sjölin, A Björklid, T Hjärn US Patent 10,575,801, 2020 | 2 | 2020 |
X-ray detector system based on photon counting C Svensson, M Persson, M Sjolin, M Danielsson US Patent App. 15/882,142, 2018 | 2 | 2018 |
Count statistics and pileup correction for nonparalyzable photon counting detectors with finite pulse length F Grönberg, M Sjölin, M Danielsson Medical Imaging 2018: Physics of Medical Imaging 10573, 253-262, 2018 | 2 | 2018 |
Compression of CT sinogram data by decimation in the view direction M Sjölin, M Danielsson Medical Physics 44 (9), e138-e146, 2017 | 2 | 2017 |
Relative calibration of energy thresholds on multi-bin spectral x-ray detectors M Sjölin, M Danielsson Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2016 | 2 | 2016 |
A method for geometric calibration of edge‐on detectors in a CT‐gantry M Sjölin, M Danielsson Medical Physics 43 (11), 6165-6174, 2016 | 2 | 2016 |
Constrained one‐step material decomposition reconstruction of head CT data from a silicon photon‐counting prototype TG Schmidt, EY Sidky, X Pan, RF Barber, F Grönberg, M Sjölin, ... Medical Physics 50 (10), 6008-6021, 2023 | 1 | 2023 |