Follow
Friedrich Wetterling
Title
Cited by
Cited by
Year
Single-Nucleotide Polymorphism of the FKBP5 Gene and Childhood Maltreatment as Predictors of Structural Changes in Brain Areas Involved in Emotional …
L Tozzi, A Carballedo, F Wetterling, H McCarthy, V O'keane, M Gill, ...
Neuropsychopharmacology 41 (2), 487, 2016
902016
Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer
F Wetterling, DM Corteville, R Kalayciyan, A Rennings, S Konstandin, ...
Physics in medicine and biology 57 (14), 4555-4567, 2012
602012
Biodistribution and pharmacokinetic studies of SPION using particle electron paramagnetic resonance, MRI and ICP-MS
OL Gobbo, F Wetterling, P Vaes, S Teughels, F Markos, D Edge, ...
Nanomedicine 10 (11), 1751-1760, 2015
402015
Sodium MRI of the human heart at 7.0 T: preliminary results
A Graessl, A Ruehle, H Waiczies, A Resetar, SH Hoffmann, J Rieger, ...
NMR in Biomedicine, 2015
362015
The design of a double-tuned two-port surface resonator and its application to in vivo Hydrogen-and Sodium-MRI
F Wetterling, M Högler, U Molkenthin, S Junge, L Gallagher, IM Macrae, ...
Journal of magnetic resonance 217, 10-18, 2012
352012
Apparent diffusion coefficient and sodium concentration measurements in human prostate tissue via hydrogen-1 and sodium-23 magnetic resonance imaging in a clinical setting at 3 T
D Hausmann, S Konstandin, F Wetterling, S Haneder, AM Nagel, ...
Investigative radiology 47 (12), 677-682, 2012
342012
A double-tuned 1H/23Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI
F Wetterling, M Tabbert, S Junge, L Gallagher, IM Macrae, AJ Fagan
Physics in Medicine & Biology 55 (24), 7681, 2010
322010
Sodium-23 magnetic resonance imaging has potential for improving penumbra detection but not for estimating stroke onset time
F Wetterling, L Gallagher, J Mullin, WM Holmes, C McCabe, IM Macrae, ...
Journal of Cerebral Blood Flow & Metabolism 35 (1), 103-110, 2015
292015
Wireless vascular monitoring implants
FM Sweeney, HS Gifford III, J Johnson, P Martin, S Raghunathan, ...
US Patent 10,806,352, 2020
282020
Investigating potentially salvageable penumbra tissue in an in vivo model of transient ischemic stroke using sodium, diffusion, and perfusion magnetic resonance imaging
F Wetterling, E Chatzikonstantinou, L Tritschler, S Meairs, M Fatar, ...
BMC neuroscience 17 (1), 82, 2016
282016
Signal-to-noise ratio of a mouse brain 13C CryoProbe™ system in comparison with room temperature coils: spectroscopic phantom and in vivo results
M Sack, F Wetterling, A Sartorius, G Ende, W Weber-Fahr
NMR in Biomedicine 27 (6), 709-715, 2014
272014
Quantitative Sodium MRI: From Pre-Clinical to Clinical Practice
F Wetterling, J Kisubi, E Haardt, S Konstandin, A Nagel, M Fatar, ...
41st annual meeting of the German Association for Medical Physics (DGMP …, 2010
27*2010
Local multi-channel RF surface coil versus body RF coil transmission for cardiac magnetic resonance at 3 Tesla: which configuration is winning the game?
O Weinberger, L Winter, MA Dieringer, A Els, C Oezerdem, J Rieger, ...
PloS one 11 (9), e0161863, 2016
262016
Impaired reward processing in the human prefrontal cortex distinguishes between persistent and remittent attention deficit hyperactivity disorder
F Wetterling, H McCarthy, L Tozzi, N Skokauskas, JP O'doherty, ...
Human brain mapping 36 (11), 4648-4663, 2015
252015
Regional and temporal variations in tissue sodium concentration during the acute stroke phase
F Wetterling, L Gallagher, IM Macrae, S Junge, AJ Fagan
Magnetic resonance in medicine 67 (3), 740-749, 2012
252012
Chemical shift sodium imaging in a mouse model of thromboembolic stroke at 9.4 T
PM Heiler, FL Langhauser, F Wetterling, S Ansar, S Grudzenski, ...
Journal of Magnetic Resonance Imaging 34 (4), 935-940, 2011
222011
Changes in inferior vena cava area represent a more sensitive metric than change in filling pressures during experimental manipulation of intravascular volume and tone
JB Ivey‐Miranda, F Wetterling, R Gaul, S Sheridan, JL Asher, VS Rao, ...
European Journal of Heart Failure, 2021
172021
Scan time reduction in 23Na-magnetic resonance imaging using the chemical shift imaging sequence: evaluation of an iterative reconstruction method
S Weingärtner, F Wetterling, S Konstandin, M Fatar, E Neumaier-Probst, ...
Zeitschrift für Medizinische Physik 25 (3), 275-286, 2015
152015
Bilateral kidney sodium‐MRI: Enabling accurate quantification of renal sodium concentration through a two‐element phased array system
R Kalayciyan, F Wetterling, S Neudecker, S Haneder, N Gretz, LR Schad
Journal of Magnetic Resonance Imaging 38 (3), 564-572, 2013
152013
Sodium-23 magnetic resonance imaging during and after transient cerebral ischemia: multinuclear stroke protocols for double-tuned 23Na/1H resonator systems
F Wetterling, S Ansar, E Handwerker
Physics in Medicine & Biology 57 (21), 6929, 2012
142012
The system can't perform the operation now. Try again later.
Articles 1–20