[CYTOWANIE][C] A Correction for the α1 α2 Doublet in the Measurement of Widths of X-ray Diffraction Lines
WA Rachinger - Journal of scientific instruments, 1948 - iopscience.iop.org
Suppose a normal beam Weissenberg photograph has been taken of the hth layer line of a
monoclinic crystal rotated about its a-axis.-4 straight line is ruled on a strip of transparent
material and this is laid horizontally across the chart at the appropriate height, xhich in this …
monoclinic crystal rotated about its a-axis.-4 straight line is ruled on a strip of transparent
material and this is laid horizontally across the chart at the appropriate height, xhich in this …
The control of humidity by saturated salt solutions
FEM O'Brien - Journal of Scientific Instruments, 1948 - iopscience.iop.org
Page 1. Journal of Scientific Instruments The Control of Humidity by Saturated Salt Solutions
To cite this article: FEM O'Brien 1948 J. Sci. Instrum. 25 73 View the article online for updates
and enhancements. Related content The control of conditioning atmospheres by saturated …
To cite this article: FEM O'Brien 1948 J. Sci. Instrum. 25 73 View the article online for updates
and enhancements. Related content The control of conditioning atmospheres by saturated …
Wide-band detector for micro-microampere low-energy electron currents
TE Everhart, RFM Thornley - Journal of scientific instruments, 1960 - iopscience.iop.org
Electrons with a mean energy of a few electron volts emerging from a source a few
millimetres in diameter are accelerated on to a positively biased plastic scintillator. The light
generated in the scintillator is guided by a Perspex light-pipe to a photomultiplier. If the …
millimetres in diameter are accelerated on to a positively biased plastic scintillator. The light
generated in the scintillator is guided by a Perspex light-pipe to a photomultiplier. If the …
The measurement of airborne droplets by the magnesium oxide method
KR May - Journal of Scientific Instruments, 1950 - iopscience.iop.org
A complete calibration has been made for the first time of the method of detecting and
measuring airborne droplets whereby the permanent impressions made when they strike a
layer of magnesium oxide smoked on a glass slide are measured microscopically. A size …
measuring airborne droplets whereby the permanent impressions made when they strike a
layer of magnesium oxide smoked on a glass slide are measured microscopically. A size …
An improved galvanic cell for determination of oxygen concentrations in fluids
FJH Mackereth - Journal of Scientific Instruments, 1964 - iopscience.iop.org
An improved membrane protected galvanic cell oxygen-temperature probe is described. The
device produces a high electrical output and displays great stability of sensitivity to oxygen
over long periods of use. It is used to determine or record oxygen concentrations in liquids or …
device produces a high electrical output and displays great stability of sensitivity to oxygen
over long periods of use. It is used to determine or record oxygen concentrations in liquids or …
Improved polythene-shielded net radiometer
JP Funk - Journal of Scientific Instruments, 1959 - iopscience.iop.org
An improved net radiometer using very thin hemispherical polythene windshields is
described. Balanced radiant heating of the windshield prevents formation of dew. Two of
these instruments, suitably matched, permit direct measurements of radiative flux divergence …
described. Balanced radiant heating of the windshield prevents formation of dew. Two of
these instruments, suitably matched, permit direct measurements of radiative flux divergence …
The cascade impactor: an instrument for sampling coarse aerosols
KR May - Journal of Scientific instruments, 1945 - iopscience.iop.org
A new instrument is described which will sample windborne and stationary aerosols such as
natural fogs and clouds, fine sprays, insecticidal mists, coarse dusts, pollen and spores, etc.
By means of four progressively finer jets impinging on glass slides in series the sample is …
natural fogs and clouds, fine sprays, insecticidal mists, coarse dusts, pollen and spores, etc.
By means of four progressively finer jets impinging on glass slides in series the sample is …
Nuclear resonance absorption circuit
FNH Robinson - Journal of Scientific Instruments, 1959 - iopscience.iop.org
Page 1. Journal of Scientific Instruments Nuclear resonance absorption circuit To cite this article:
FNH Robinson 1959 J. Sci. Instrum. 36 481 View the article online for updates and enhancements.
Related content On matching a nuclear resonance circuit to an amplifier with an application to …
FNH Robinson 1959 J. Sci. Instrum. 36 481 View the article online for updates and enhancements.
Related content On matching a nuclear resonance circuit to an amplifier with an application to …
The accuracy of the bubble meter method for gas flow measurements
A Levy - Journal of Scientific Instruments, 1964 - iopscience.iop.org
The bubble meter technique is an absolute method of measuring the volume flow rate of
gases. It requires accurate standards of mass and time only and is simple in application.
This paper describes the method, examines its potential accuracy and derives criteria for …
gases. It requires accurate standards of mass and time only and is simple in application.
This paper describes the method, examines its potential accuracy and derives criteria for …
Instruments for the measurement of the visual range
RG Beuttell, AW Brewer - Journal of Scientific Instruments, 1949 - iopscience.iop.org
It is often necessary to know the visual range orvisibility'at times when a direct observation
onvisibility marks' is not possible. This note describes a series of instruments of small size in
which the visibility is measured by measuring directly the scattering coefficient of a relatively …
onvisibility marks' is not possible. This note describes a series of instruments of small size in
which the visibility is measured by measuring directly the scattering coefficient of a relatively …