[ZITATION][C] Chloride Content of Portland Cement Concrete Powder by a Method Using Flocculation
K Ramamurti, GP Jayaprakash - Transportation Research Record, 1991 - trid.trb.org
K Ramamurti, GP Jayaprakash
Transportation Research Record, 1991•trid.trb.orgA simple and rapid method of determining chloride in portland cement concrete powder is
described. This method can be used under field conditions in a portable laboratory. An
organic flocculant is used to flocculate the insoluble portion from a portland cement concrete
powder suspension in hot water. The clear decant is analyzed for chloride content using a
chloride ion-selective electrode.
described. This method can be used under field conditions in a portable laboratory. An
organic flocculant is used to flocculate the insoluble portion from a portland cement concrete
powder suspension in hot water. The clear decant is analyzed for chloride content using a
chloride ion-selective electrode.
A simple and rapid method of determining chloride in portland cement concrete powder is described. This method can be used under field conditions in a portable laboratory. An organic flocculant is used to flocculate the insoluble portion from a portland cement concrete powder suspension in hot water. The clear decant is analyzed for chloride content using a chloride ion-selective electrode.
trid.trb.org